537
Troubleshooting
HMI displays or logs
Fault code F0105
Does the HMI also
display F0008, F0095,
or condenser fan no
contact?
No
Yes
Refer to the corresponding error
troubleshooting tree.
Visually inspect condenser fan 1
and 2.
Is either fan damaged,
obstructed, or otherwise
unable to turn freely?
Yes
Clear obstruction or replace fan.
Inspect fuse F4 in the 24V fuse
box C20.
Continued on next page
WARNING:
Electrical hazard.
Follow Safety Warnings and High
Voltage Shutdown Procedures
defined in the Service Manual
and Diagnostic Guide.