541
Troubleshooting
Replace condenser fan 1.
Is the error resolved?
No
Yes
Complete
Replace condenser fan 2.
Continued from previous page
With a multimeter, check for continuity between the
following points:
- Continuity : Resistance is less than or equal to
2ohms.
Condenser fan 1 C89
Connector pin
Condenser fan 1 C89
Connector pin
Pin 3
Pin 4
Condenser fan 1 C89
Connector pin
Pin 8
Ground
Ground
Condenser fan 1 C89
Connector pin
24V fuse box C20
Terminal
Pin 6
C5
Condenser fan 1 C89
Connector pin
Pin 1
A5
24V fuse box C20
Terminal
No
Is there any evidence of
continuity loss?
Yes
Defective harness.
Replace harness.
No
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...