572
Troubleshooting
HMI displays or logs
Fault code F0158
Does the HMI
also display error
F0026?
No
Yes
Refer to F0026 troubleshooting
tree.
Disconnect connector C71 from
A/C compressor.
With a multimeter, check the voltage between the
following points:
AC compressor C71
Connector pin
Pin 3
Pin 6
AC compressor C71
Connector pin
Is there any problem with
the connector integrity?
Yes
No
Defective connector.
Replace the connector as described in the “Wire
Harness Connector Identification, Location, and
Service Chart” in the Service Manual
Continued on next page
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...