578
Troubleshooting
With a multimeter, check for continuity between the
following points:
- Continuity : Resistance is less than or equal to
2ohms.
Condenser fan 1 C89
Connector pin
Condenser fan 1 C89
Connector pin
Pin 3
Pin 4
Condenser fan 1 C89
Connector pin
Pin 8
Ground
Ground
Condenser fan 1 C89
Connector pin
24V fuse box C20
Terminal
Pin 6
C5
Condenser fan 1 C89
Connector pin
Pin 1
A5
24V fuse box C20
Terminal
Continued from previous page
Refer to the CAN investigation
subtree.
Investigate CAN C network.
Is the error still raised?
Yes
No
Complete
Defective condenser fan 1.
Replace condenser fan 1.
Is there any evidence of
continuity loss?
Yes
Defective harness.
Replace harness.
No
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...