621
Troubleshooting
Continued from previous page
Is there any proof of a
short-circuit to the ground
in the main low voltage
distribution circuit?
Yes
Defective wiring.
Replace any defective wiring.
With a multimeter, check for short circuit between the
following points:
-LV short: Resistance measurement is less than 100k-
ohms.
-Inspect all connectors and wires between the two test
points of the harness ends.
RT020
GND strip1
Battery RT020 Ground
Connector pin
RT014
GND strip1
Low voltage Ground
Connector pin
RT013
GND strip1
RT009
GND strip1
RT017
GND strip1
RT011
GND strip1
RT010
GND strip1
RT087
GND strip1
No
No
Continued on next page
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...