647
Troubleshooting
HMI displays or logs
Fault code F0156 and
Signal validity code 1/2/31
Does the HMI also display
‘’Please update software for
CCU/FSVCU’’?
No
Yes
Update the supervisory
controller software following
the procedure provided in the
maintenance manual.
Does the HMI also
display F0095 or F0104?
No
Yes
Refer to the corresponding
troubleshooting tree.
Were you able to find a
problem in the CAN D
network?
Yes
No
Refer to CAN investigation subtree
Repair according to the
actions prescribed in the
subtree.
Is the error code still
displayed?
Yes
No
Complete
Contact Dana for further
investigation.
Does the HMI also
display
‘’Supervisory controller
No contact’’?
No
Yes
Refer to the corresponding error
troubleshooting tree.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...