686
Troubleshooting
HMI displays
“Powertrain cooling pump
No contact.”
Check the HMI for other faults.
Does the HMI also
display “F0008 - 12V/
24V Charging System
Fault”?
No
Yes
Refer to error F0008
troubleshooting tree.
Disconnect connector C81 from
coolant pump.
Remove fuse F6 and F16 in order
to take continuity measures
from inside the fuse box.
Wait for 10 minutes before
operating on the truck.
Turn ignition OFF.
Inspect fuse F6 in the 24V fuse
box C20.
Is fuse F6 blown or
intermittent?
No
Yes
Is fuse F16 blown or
intermittent?
No
Yes
Inspect fuse F16 in the 24V fuse
box C20.
Continued on next page
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...