Troubleshooting
F0015 - PTO unavailable
Error Description
Possible Causes
Possible Solutions
ePTO is offline.
1) ESS, DCDC, or LV distribution
fault.
2) Blown 12V fuse F11.
3) Loss of continuity due to
defective LV connector or
harness.
4) Loss of continuity due to
defective HV connector or
harness.
1) Troubleshoot specific error.
2) Replace 12V fuse F11.
3) Replace LV connector or
harness per Service Manual.
4) Replace HV harness.
Note:
Connectors may vary from what is
shown depending on ePTO configuration.
Connector C6
(orientation depends on ePTO configuration)
Connector C15S (socket)
Connector C15P (pin)
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...