74
Troubleshooting
F0026 (Fault Reason 17)
Error Description
Possible Causes
Possible Solutions
BMS has detected that the
temperature in one or more cells is
too low.
1) Low ambient temperature.
1) Troubleshoot the error.
The temperature threshold for this error is -31°F
(-35°C).
HMI displays or logs
Fault code F0026 and
BMS fault reason 17
Was the vehicle
trying to be operated or
charged below -35°C?
No
Yes
HV batteries do not function
below -35°C.
Complete
Move the vehicle to a location
where ambient temperature is
above 0°C. Allow batteries to
warm to greater than -25°C.
Does the fault code
reappear?
No
Yes
Contact DANA for
further investigation.
Turn vehicle ON in ready mode for
1 hour or charge vehicle for at
least one hour.
Charge vehicle if SOC is
below 30%.
Does the fault code
reappear?
Yes
No
Complete
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...