89
Troubleshooting
F0026 (Fault Reason 36)
Error Description
Possible Causes
Possible Solutions
BMS has detected an abnormal
heating rate in the ESS heating
circuit.
1) Defective harness between S-
Box and battery pack(s).
1) Replace harness.
The heating circuit is powered from the S-Box and
runs through each ESS battery pack. If there is a
problem with the heating circuit, it is either internal to
a battery pack or is within the wiring harness
between the S-Box and battery pack.
If the defect is inside one of the battery packs, the
battery pack will need to be replaced.
HMI displays or logs
Fault code F0026 and
BMS fault reason 36
Remove dust shield from ESS.
Which ESS option is
installed on the truck?
282kWh
141kWh
WARNING:
Electrical hazard.
Follow Safety Warnings and High
Voltage Shutdown Procedures
defined in the Service Manual
and Diagnostic Guide.
Summary of Contents for SPICER PACCAR 220ev
Page 263: ...263 Troubleshooting Connector C53 Connector C100...
Page 274: ...274 Troubleshooting Connector C717 green Connector C718 yellow Connector C719 orange...
Page 322: ...322 Troubleshooting Connector C651 B Circuit73...
Page 468: ...468 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 476: ...476 Troubleshooting Connector C44 Connector C45 Connector C53 Connector C54 Connector C661...
Page 514: ...514 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 636: ...636 Troubleshooting Connector C676 Connector C651 B Circuit73...
Page 702: ...702 Troubleshooting Connector C101 Connector C713 Connector C722 3 4 3 4...
Page 711: ...711 Troubleshooting Connector C101...
Page 730: ...730 Troubleshooting Connector C651 A...
Page 733: ...733 Troubleshooting Connector C651 A...
Page 736: ...736 Troubleshooting Connector C651 B Circuit73...
Page 738: ...738 Troubleshooting Connector C651 B Circuit73...