TG-0057_19 TM4 SUMO HD CO300-A1_A2_A2.5 Installation Guide
© Dana TM4 inc., 2013-2020
Page 19 of 42
2020-11-20
4.4.3 Serial configuration
Although it is recommended that you use a parallel cooling configuration, a serial cooling configuration can
also be used in your integration, see Figure 5.
Note
: Coolant liquid pressure must not reach or exceed 30 PSI.
Figure 5
Serial cooling system
See the System Specifications [5] for more information on coolant pressure drops and rate flow
management.
4.4.4 Coolant inlet/outlet specifications
Specific hose types should be used to connect the cooling unit to this system. Refer to the product interface
drawing [11] for coolant inlet/outlet specifications; the locations of the inlet and outlet are labelled on the
MCU casing (Figure 6).
See the System Specifications [5] for more information on coolant pressure drops and flow rate
management.
Figure 6
Coolant inlet/outlet locations on the MCU