Unpacking and Inspecting  

SERVO

STAR

®

 

SP3 Power Block 

UNPACKING AND INSPECTING 

Open the box and remove all the contents. Check to ensure there is no visible damage to any of 
the equipment. 

 

Electronic components in this amplifier are design-hardened to reduce static 
sensitivity. However, proper procedures should be used when handling to avoid 
damage to equipment. 

 

Remove all packing material and equipment from the shipping container. Be aware 
that some connector kits and other equipment pieces may be quite small and can be 
accidentally discarded if care is not observed when unpacking the equipment. Do not 
dispose of shipping materials until the packing list has been checked. 

 

Upon receipt of the equipment, inspect components to ensure that no damage has 
occurred in shipment. If damage is detected, notify the carrier immediately. Check all 
shipping material for connector kits, documentation, diskettes, CD-ROM, or other 
small pieces of equipment. 

WARRANTY INFORMATION 

All products covered in this manual are warranted to be free of defects in material and 
workmanship and to conform to the specifications stated either in this document or product 
catalog description. All Kollmorgen brushless motors and electronics are warranty for a period of 
24 months from the time of installation or 30 months from time of shipment, which ever comes 
first. There are no other warranties, expressed or implied (including the warranty of 
merchantability and fitness for a particular purpose, which extends beyond this warranty. 
Kollmorgen warrants that the products covered in the manual are free from patent infringement 
when used for normal purposes. 

USE AS DIRECTED 

The following guidelines describe the restrictions for proper use of the SERVO

STAR

 SP3 

Power Block: 
1. 

The amplifiers are components built into electrical equipment or machines and can only 
be used as integral components of such equipment. 

2. 

The servo amplifiers are to be used only on earthed three-phase industrial mains supply 
networks (TN-system, TT-system with earthed neutral point). 

3. 

The servo amplifiers must not be operated on power supply networks without an earth or 
with an asymmetrical earth. 

4. 

If the servo amplifiers are used in residential areas, or in business or commercial 
premises, you must implement additional filter measures. 

5. 

The servo amplifiers are only intended to drive brushless synchronous servomotors with 
closed-loop control of torque, speed, and position. The rated voltage of the motors must 
be at least as high as the DC-link voltage of the servo amplifier. 

www.szcxi.com |  From

KOLLMORGEN

Summary of Contents for Kollmorgen SERVOSTAR SP3

Page 1: ...Danaher Motion SERVOSTAR SP3 Power Block Installation Manual KOLLMORGEN giving our customers freedom of design M SS 010 0104 www szcxi com From KOLLMORGEN...

Page 2: ...e Kollmorgen Corporation Therefore information contained in this manual may be updated from time to time due to product improvements etc and may not conform in every respect to former issues Not for u...

Page 3: ...d metal grounded surface Keep all covers and cabinet doors shut during operation Otherwise potential hazards could cause severe personal injury or damage to the product Be aware that during operation...

Page 4: ...ves have been tested by an authorized testing laboratory in a defined configuration with the system components deSP3 Power Blockribed in this documentation Kollmorgen is not responsible for any diverg...

Page 5: ...lated Cable Clamp 13 Alternative Bonding Methods 13 SYSTEM WIRING 15 MAIN POWER CONNECTOR 15 24V LOGIC POWER CONNECTOR OPTIONAL 16 STANDARD OPTION 17 Standard Option Block Diagram 18 INTEGRATED 8F OPT...

Page 6: ...Kollmorgen Safety Instructions SERVOSTAR SP3 Power Block ii CURRENT SCALING 25 CUSTOMER SUPPORT 26 www szcxi com From KOLLMORGEN...

Page 7: ...r additional details Metal to metal contact is important for electrical noise control 3 Wire the SP3 Power Block according to the System Wiring Diagram Pay particular attention to the pinout connector...

Page 8: ...d option A Connect the cable C2 B Connect the 8F Delta Tau accessory 13 Configure the SP3 Power Block for your particular motor if this was not done at the factory 14 Tune the SP3 Power block for the...

Page 9: ...rgen brushless motors and electronics are warranty for a period of 24 months from the time of installation or 30 months from time of shipment which ever comes first There are no other warranties expre...

Page 10: ...servo amplifiers with the standards for industrial areas stated in the front of this manual only if Danaher Motion Kollmorgen delivers the components motors cables amplifiers etc PART NUMBER CP3 03 2...

Page 11: ...volts 22 27 Power 24VDC Ext Logic Current amps sink 0 5 SoftStart Max Surge Current amps 30 Max Charge Time sec 0 25 Fault Contact Rating 1A Fault Contact Closing Period mSec Close 3mS Open 2mS OverTe...

Page 12: ...Cx10 External Shunt Peak current amps 20 Regulator Minimum resistance 20 Watts 200 Capacitance Farads 0 00082 0 00164 Application BUS Voltage nominal VDC 325 Information VHYS Regen circuit turn off V...

Page 13: ...2lb in 1 35Nm Hardware Motor Screw Size Torque Ground Screw Size Torque Control Logic AWG mm2 28 16 0 5 1 5 Motor Line AWG mm2 14 0 25 Main Input AWG mm2 14 25 12 4 Configurable I O wire gauge 22 18 A...

Page 14: ...To ensure proper grounding and to optimize EMC the enclosure should have continuous ground continuity maintained between all metal panels This ground continuity is intended to be both a safety ground...

Page 15: ...al ground The second is radiated high frequency emissions that are usually capacitively coupled from line to line and are differential in nature To properly mount the filters the enclosure should have...

Page 16: ...The filtering of the lines feeding the motor provides additional attenuation of noise currents that may enter surrounding cables and equipment I O ports in close proximity Differential mode currents...

Page 17: ...n Schaffner RD7137 36 0m5 A 96843 005 500 H 3 phase common mode choke 36 amps continuous Schaffner RD8137 64 0m5 A 96843 010 500 H 3 phase common mode choke 64 amps continuous I O Filtering I O filter...

Page 18: ...d This high frequency ground is made with the use of a flat braid or copper bus bar Do not use a standard wire for the high frequency ground When connecting high frequency grounds use the shortest bra...

Page 19: ...lide onto the bus bar The cable with exposed shield is inserted through the SK piece and the thumbscrew on top of the SK piece is used to tighten the connection between the cable shield and the bus ba...

Page 20: ...Power Block 14 copper bus bar cable shield compressed on copper bus bar Thumb screw to tighten down shield to bus bar SK 8 14 20 Shielded terminal block Phoenix Contact Side View Phoenix Contact Top V...

Page 21: ...SERVOSTAR SP3 Power Block has two options the Standard Option and the Integrated 8F Option The Integrated 8F Option includes the interface features of the Delta Tau Data Systems Inc s Accessory 8F di...

Page 22: ...B L3 L2 L1 THE SERVOSTAR SP3 OPERATES WITH VOLTAGES AS HIGH AS 230 VAC USE CAUTION REFER INSTALLATION AND TROUBLESHOOTING TO QUALIFIED PERSONNEL ONLY WARNING HIGH VOLTAGE MAY EXIST UP TO 5 MINUTES AFT...

Page 23: ...WMABOT Command Phase A bottom command 11 PWMBTOP Command Phase B top command 12 PWMBBOT Command Phase B bottom command 13 PWMCTOP Command Phase C top command 14 PWMCBOT Command Phase C bottom command...

Page 24: ...s option has four connectors C1 to C4 on the front panel and one connector C5 on the top of the unit The PMAC2 has up to 4 machine interface connectors labeled JMACH1 through JMACH4 Each JMACH connect...

Page 25: ...bles can refer to Appendix A for drive motor pinout connections Connector C1 Hall Effect Device Feedback Connector C1 interfaces between the SP3 and the Hall Effect Devices HED on the motor These sign...

Page 26: ...Return PMAC_GND 8 EV5 Return E5V Return PMAC_GND 9 Hall 1 Hall 1 H1 10 Hall 2 Hall 2 H2 11 Hall 3 Hall 3 H3 12 Shield Shield SHIELD 13 Thermostat High Thermostat High MOTOR THERMp 14 Shield Shield SH...

Page 27: ...22 B11 NC Not Connected 23 A12 ACLK Input A D Converter Clock 24 B12 ACLK Input A D Converter Clock 25 A13 ASTB Input A D Converter Strobe 26 B13 ASTB Input A D Converter Strobe 27 A14 ADAA Output Ch...

Page 28: ...below Connector C5 User Flags PIN SYMBOL FUNCTION DESCRIPTION 1 USER Input General Capture Flag 2 PLIM Input Positive Limit Flag 3 MLIM Input Negative Limit Flag 4 HOME Input Home Flag 5 FL_RT Input R...

Page 29: ...mplifier over current F 1100 PWM fault frequency A1 1010 12V under voltage A2 1010 12V under voltage A3 1010 5V under voltage A4 1010 Reference under voltage The following provides a description of so...

Page 30: ...on t1 1011 Over current shut down t2 1011 Motor over temperature t3 1011 Power amplifier over temperature o 1101 Power amplifier over voltage u 1110 Power amplifier under voltage Watch dog P1 1001 Dri...

Page 31: ...Enabled factory default Open Closed Enabled Closed Open Enabled CURRENT SCALING The SP3 measures the current of the drive and makes the value available to the user via a 10 volt signal The currents me...

Page 32: ...ive way contact your local sales representative for order status and delivery information product information and literature and application and field technical assistance If you are unaware of your l...

Reviews: