82
Clear Motion Task
UA FC = 65 Id = 10 Motion Task Number (16bit)
CRC
UA FC = 65 Id = 10 Minimum Wait Time (16bit)
CRC
The Minimum Wait Time is the time the master must wait at least before sending the next
request. Motion Tasks are stored in the program FLASH. During write access the FLASH
cannot be accessed and communication is down until the FLASH is back into normal
operation.
7.7.6
Clear All Motion Tasks
UA FC = 65 Id = 11 CRC
UA FC = 65 Id = 10 Minimum Wait Time (16bit) CRC
The Minimum Wait Time is the time the master must wait at least before sending the next
request. Motion Tasks are stored in the program FLASH. During write access the FLASH
cannot be accessed for program execution and communication is down until the FLASH
is back into normal operation.
7.8
M
OBUS
A
DDRESS AND FUNCTION
T
ABLES
The following tables contain the required data for implementing Modbus commands. The
advanced user may determine that functions other than these will show up in the GUI
Variable browser. The functions listed here are the only functions supported by the
Modbus communication.