CAUTION
A possible ignition hazard within the MMC exists if the maximum currents list-
ed for Bus 2 or Bus 3 are exceeded or if excessive current is drawn at the 24
V line going into the MMC. If these currents might be exceeded (due to im-
proper wiring or external device failure), circuit breakers or fuses should be
used in series with the 24 Vdc going to and coming from the MMC. Specifi-
cally, the circuit breakers or fuses should be sized for 10 A total on the 24 Vdc
line coming into the MMC, 1 A total from the +24 Vdc OUT pins of the AXIS
and AUXILIARY I/O connectors, and 5 A total from the I/O 24V pins of the
GENERAL I/O connector. For maximum protection, use fast blow fuses.
When using molded cables supplied by Danaher Motion to connect the MMC
to the drives, no overload protection is required.