background image

P-264-10   9/04  

Printed in U.S.A.

Danaher Motion

1300 N. State St.

Marengo, Il. 60152

Phone: 1-800-554-8466

Fax: 1-800-445-0329

E-mail: linear@danahermotion.com

Literature: litrequest@danahermotion.com

Or write:

Danaher Motion

1300 N. State St.

Marengo, Il. 60152

Summary of Contents for THOMSON D12-05B5

Page 1: ...Electrak 10 Series Electromechanical Linear Actuator www danahermotion com Installation Operation Manual...

Page 2: ...duct transportation charges prepaid to the appropriate Danaher factory Additional warranty information may be obtained by writing the Customer Service Department Danaher Motion 1300 N State St Marengo...

Page 3: ...500 or 1000 lbs Power Input 24 VDC Stroke Lengths 4 8 12 18 or 24 inches Feedback 10K ohm potentiometer Other Actuator Products Electrak 1 Nominal load capacities in a small package Load Ratings 25 o...

Page 4: ...CS 2015 and the control of the PC compatible MCS 2020 in a single enclosure for ease of installation and wiring MCS 2020 A control that can be used with the MCS 2015 or other 12 or 24 VDC power source...

Page 5: ...and should not be used in underwater conditions 5 Electrak 10 actuators are not explosion or dust ignition proof do not use in those types of environments 6 Electrak 10 actuators are factory lubricate...

Page 6: ...or to bind The load should act along the stroke axis of the actuator since off center loads may cause binding and lead to premature failure See Figure 2 The actuator mounting brackets must be able to...

Page 7: ...actuator and power source 44 feet for example indicates the wire gauge required 12 SWITCHES Actuator direction forward reverse is controlled with a double throw switch with the center position 11 off...

Page 8: ...015 Power Supply 110 VAC in 24 VDC out 17 Amp maximum MCS 2020 Actuator Controller Capable of extend and retract functions in a jog or continuous run model For use with 12 or 24 VDC actuators MCS 2025...

Page 9: ...Solution No voltage or amp draw Actuator not receiving power Check power supply Proper voltage no amp draw Dead motor Replace motor Thermal overload cut out Let cool check duty cycle when overheated...

Page 10: ...DIMENSIONS The outline drawing shown below describes Electrak 10 ball bearing screw driven actuators The tabulated dimension chart shows these lengths for each model and also describes the part number...

Page 11: ......

Page 12: ...U S A Danaher Motion 1300 N State St Marengo Il 60152 Phone 1 800 554 8466 Fax 1 800 445 0329 E mail linear danahermotion com Literature litrequest danahermotion com Or write Danaher Motion 1300 N St...

Reviews: