The Veeder-Root brand Series 7990 is the best value in a low cost, versatile indicator
for industrial applications.  Highly flexible, it can be programmed at installation to
operate as a totalizer, rate indicator  (Model 799008-201 only), or elapsed time meter.
With this unique functionality, it can be used to totalize parts production, keep track
of machine hours, indicate process times, or show production rate.  Input scaling
accommodates a variety of signal sources with the ability to readout in meaningful
engineering units.  Use two or three of them and have matching control panel
instrumentation for count, speed, and time.  Standardize them throughout your
plant, and reduce inventory by stocking just one indicator instead of several.

Many convenience features are included, such as adhesive labels preprinted with
popular engineering unit identifiers, security locks for reset and programming, and
accessory snap-on adaptor modules.  The adaptor modules allow screw-terminal wire
connection and/or accommodation of high-voltage input signals for timing or
counting applications.  Accessory
panel adapters, available with or
without a locking key reset, allow
easy mounting and retrofit to
older and larger mechanical,
electrical or electronic products.

Features

Large, easy to read 8-digit LCD (5-digit,
rate mode)

Heavy, diecast enclosure for industrial
duty application

Simple programming procedure selects
operating mode and other functions

Tamper proof programming mode lock

Operates without external power – long life
lithium battery

Totalizer mode has input scaling and
selectable decimal point

Rate mode utilizes a time interval method
for improved accuracy.

Timer modes for hours, minutes, seconds
with choice of time increment

Front panel reset, remote reset, or
nonreset operation

Overview

Construction

page 2

Rear Panel Features

page 2

Specifications

page 3

Panel Mounting

page 3

Setup

Wiring

page 4

Front Panel Operation

page 4

Count Mode

page 5-6

Hour Meter Mode

page 6

Timer Mode

page 6

Rate Meter Mode

page 6-7

Option Modules

page 7-8

General

Warranty

page 8

Index

Veeder-Root 

brand 

Summary of Contents for Veeder-Root 7990 Series

Page 1: ...ssory snap on adaptor modules The adaptor modules allow screw terminal wire connection and or accommodation of high voltage input signals for timing or counting applications Accessory panel adapters a...

Page 2: ...ifies programmed function Count Rate Timer Hour Meter Mode Indicators Large LCD Display Long Life Internal Battery Lithium cell provides continuous ON operation Nonvolatile data and program memory Rea...

Page 3: ...able from 0 to 4 places 0 to 3 places for Rate Power Source Internal Lithium Battery Battery Life Eight year typical life Temperature Range 0 to 75 C 32 to 167 F Inputs High Speed Count Speed 10 KHz 5...

Page 4: ...reset the present value in Count or Timer mode The Reset function will only be activated if the Reset Enable jumper is set to the ON position or if the rear terminal Reset Enable input pins 4 and 5 i...

Page 5: ...gic which indicates whether counting is done on only the falling edge 1 of the input or both the rising and falling edge of the input 2 Use the reset key to toggle between the two values Default is 1...

Page 6: ...splay resolution has been set depressing the stylus key will cause the unit to return to Operating mode S E C In Timer mode the unit accumulates time whenever the input is held active The reset button...

Page 7: ...Pulses per Display Unit 1 360 X 60 1 167 Gallons per hour can be displayed using a 20 pulse per gallon flow meter as the input by setting the Prescale Value according to the formula below Revolutions...