The V3-BT unit cannot be turned off after installation, so any doors installed with the V3-
BT etc. must not operate near health care facilities when any regulations posted in these 
areas prohibit the use of wireless phones or two-way radios. Hospitals and health care 
facilities may be using equipment that could be sensitive to external RF energy. 
 
 

Potentially Explosive Atmospheres 

The V3-BT unit cannot be turned off after installation, so any building installed with V3-BT 
etc. must not be located in an area with a potentially explosive atmosphere and obey all 
signs and instructions not to use V3-BT in such areas. Sparks in such areas could cause 
an explosion or fire resulting in bodily injury or even death. 
 
Areas with a potentially explosive atmosphere are often, but not always marked clearly. 
Potential areas may include: fueling areas (such as gasoline stations); below deck on 
boats; fuel or chemical transfer or storage facilities; areas using liquefied petroleum gas 
(such as propane or butane); areas where the air contains chemicals or particles (such as 
grain, dust, or metal powders); and any other area where it would normally be advisable 

not to

 install the V3-BT. 

 
 

Specific Human Absorption Rates (SAR) 

THE V3-BT UNIT IS NOT DESIGNED TO BE WORN ON A PERSON’S BODY. AS SUCH, 
BODY WORN TEST POSITIONS FOR THE V3-BT UNIT ARE NOT REQUIRED BY 
EITHER THE IEC 62311 FOR BLUETOOTH LE OR FCC/IEEE/ICNIRP REQUIREMENTS 
FOR BLUETOOTH LE. 
 
The V3-BT unit is not intended for handheld use or to be worn on the body. A minimum 
separation of eight (8”) inches (20 cm) is to be maintained between the V3-BT and any 
persons’ body. Additional information on Specific Absorption Rates (SAR)

 

Battery Safety Information 

Adhere to the following guidelines to avoid the risk of fire or explosion: 
 
1.  Dispose of the used battery according to the instructions provided with the battery. 
2.  Do not drop, puncture, disassemble, mutilate, or incinerate the battery. 
3.  Touching both terminals of a battery with a metal object will short circuit the battery. Do 

not carry batteries loosely if the contacts may touch coins, keys, and other metal 
objects (such as in pockets or bags). 

4.  Do not stack batteries taken out of the carry case. 
5.  Do not heat the batteries to try to rejuvenate their charge. 
6.  Do not exceed the temperature ranges or other environmental conditions specified by 

the battery manufacturer. 

7.  Never use the V3-BT without the battery cover installed. 
 
 
 

 

Summary of Contents for V3-BT

Page 1: ...V3 BT Danalock V3 BT Technical Manual v 1 5 May 2017 Page 1 V3 BT Technical Manual Version 1 5 May 2017...

Page 2: ...vered standard content 11 Installing the unit 12 Practical installation advice 12 Functionality check 13 LED signals 13 Electro mechanical lock classification 14 Product family 15 Accessories 15 Warra...

Page 3: ...ol after sales service whose agreement is mandatory prior to any replacement Any shipping costs are at the Customer s expense The warranty does not apply to visible defects Also excluded are defects a...

Page 4: ...ERIALS AND ANY EMBEDDED SOFTWARE FIRMWARE AND UPDATES THERETO INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF DATA OR ANY OTHER PECUNIARY LOSS REGARDLES...

Page 5: ...for radio terminal equipment supporting Bluetooth Low Energy 2400 2483 5 MHz ACMA AUS NZ The V3 BT product complies with the Australian New Zealand Radio communication Act for radio terminal equipment...

Page 6: ...site links to the My Danalock site from Poly Control ApS and it is found at my danalock com V3 BT devices can be integrated to the My Danalock site Safety first Simple Guidelines Please follow these...

Page 7: ...e doors or internal residential doors EN 14846 category of use classification grade 0 Durability door mass and closing force and security Physical attack The type of door i e mass and closing force du...

Page 8: ...is shielded from RF signals However certain electronic equipment may not be shielded against the RF signals generated by the V3 BT unit Pacemakers The Health Industry Manufacturers Association recomm...

Page 9: ...l powders and any other area where it would normally be advisable not to install the V3 BT Specific Human Absorption Rates SAR THE V3 BT UNIT IS NOT DESIGNED TO BE WORN ON A PERSON S BODY AS SUCH BODY...

Page 10: ...e Internet browsers you use and information about the way you use the Application Data retention policy managing your information We will retain User Provided data for as long as you use the Applicati...

Page 11: ...ng and disclosing information all of which activities will take place in Scandinavia Europe Middle East Asia and United States Contact us If you have any questions regarding privacy while using the Ap...

Page 12: ...he unit Practical installation advice Please follow the installation guide carefully It is available on the danalock site that is found at https guide danalock com Be aware that multiple installation...

Page 13: ...ion Constant red light till finishes Manually lock unlock when not calibrated Constant yellow light till finishes Lock has been latched successfully Constant yellow till fails then one red blink Lock...

Page 14: ...ence from other Bluetooth devices Apple products will typically be ranked higher than other Bluetooth devices Electro mechanical lock classification The V3 BT is categorized as an electro mechanical l...

Page 15: ...or the V3 series Description Bluetooth Wi Fi Wireless Keypad X KeyFob one click access without a smartphone X Bridge remote operate the lock X X Warranty Poly Control ApS products are covered by a lim...

Page 16: ...pport when they receive the following information about the unit 1 Serial number preferred MAC address or alias of the lock 2 Username used when registering installing the lock 3 Username used when ge...

Page 17: ...ated antennas and battery Connections Operational voltage supply voltage 4 x 3V DC 12V DC Standby time on the battery 450 days for V3 BT models Temperature range In active running mode 20 C to 40 C St...

Page 18: ...product complies with Part 15 of the FCC rules and with Industry Canada license exempt standard s Operation is subject to the following two conditions 1 This device may not cause harmful interference...

Page 19: ...ions de la FCC aux conditions pr vues pour un environnement non contr l Cet quipement doit tre install et fonctionner une distance minimale de 20 cm entre l appareil irradiant et votre corps Cet mette...

Page 20: ...The V3 BT product complies with the essential requirements of the RED Directive 2014 53 EU as stated by the EC Declaration of Conformity Certificates and Declaration of conformity DOC statements can...

Reviews: