background image

- 18 -

Clicks

Color

Activity

1

Green

Inclusion mode

This mode is used to in- or exclude your Danalock with a Z-Wave or Zigbee 

gateway. When the Danalock blinks green it is in ex/inclusion mode and you 

have 30 seconds to pair the Danalock with a gateway.

2

Yellow

Manual calibration

Turn the Danalock to the desired unlocked position. Start the calibration 

with the click command and wait for the LED to start blinking yellow. Turn 

the Danalock to the desired locked position while the LED blinks and click 

the button once to save the locked position. If the lock doesn’t receive a 

response from you within 30 seconds the calibration will be canceled.

3

White

Auto calibration

Turn the Danalock to unlocked position and lift the handle if needed. Leave 

the door open while the Danalock auto calibrates. Start the auto calibration 

with the click command. The Danalock will blink white while auto calibrating.

7

Cancel

10

Red

Reset user settings

This action deletes all user settings on the Danalock. The Danalock responds 

by blinking red.

Reviews: