Manual 1.1 en

Summary of Contents for Z5330.050

Page 1: ...D Z5330 050 Manual 1 1 en ...

Page 2: ...b website for the latest version of this manual When reselling this product hand over this manual to the new customer If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the systems If you require additional manuals for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Strasse 134 D 71522 Backnang Germany...

Page 3: ...6 3 1 Intended use 6 3 2 Rear panel 6 3 2 1 AMP 1 AMP 2 AMP 3 6 3 2 2 MAINS SUPPLY 7 3 3 Front panel 7 3 3 1 MAINS 7 3 3 2 AUXILIARY MAINS OUTPUTS 16 A 7 3 3 3 4 CH OUTPUTS NL8 8 3 3 4 6 CH OUTPUTS6 CH OUTPUTS LKS 19 F 8 3 3 5 NL8 F LKS 19 F Pin assignments 9 4 Z5338 I O Panel 10 4 1 INPUT 10 4 2 INPUT LINK 10 4 3 REMOTE 10 5 Z5333 Rack link 12 6 Manufacturer s Declaration 13 Contents d b Z5330 05...

Page 4: ...es 1 2 Scope of supply Before starting up please verify the shipment for completeness and proper condition of the items If there is any sign of obvious damage do not operate the rack assembly and contact your local dealer from whom you received it Pos Qty d b Code Description 1 1 Z5330 050 Touring rack assembly NEMA L21 30 with shock mounted 19 frame Including 2 1 X5336 Mains power distribution NE...

Page 5: ... 5 m 1 6 ft at the front and rear of the touring rack to ensure sufficient cooling airflow D80 Touring rack assemblies can be positioned side by side or stacked When combining the Z5330 D80 Touring rack assembly with the Z5310 D12 Touring rack assembly or any other rack assembly that produces an opposing airflow observe the following restrictions D12 D80 Touring rack assemblies can be positioned s...

Page 6: ...nect the unit to mains power supplies with protective earth only If there is any sign of obvious damage to the power cord and or NEMA mains connector do not use the unit and replace it before further use Please ensure the mains connector is accessible at any time to disconnect the unit in case of malfunction or danger Do not connect or disconnect the NEMA mains connector under load or live 3 2 Rea...

Page 7: ...f the onsite mains supply lines phase conductor L1 L2 L3 3 3 2 AUXILIARY MAINS OUTPUTS 16 A Three auxiliary mains outputs powerCON sockets are provided One socket is mounted on the front and two sockets on the rear panel They are intended for the connection of low current devices such as notebooks or additional Ethernet switches Each socket can be switched on and off by its dedicated switch These ...

Page 8: ...ries the output signals of all four channels of the amplifier with the following pin assignment 1 Channel A pos neg 2 Channel B pos neg 3 Channel C pos neg 4 Channel D pos neg Please refer to the corresponding channel assignment label above each connector as shown in the graphic opposite 3 3 4 6 CH OUTPUTS6 CH OUTPUTS LKS 19 F The 6 CH OUTPUTS multipin connectors LKS 19 are used in connection with...

Page 9: ...ND GND CH C 3 CH C 3 2 1 L N CH D 4 CH D 4 3 2 L N AMP 2 CH A B C D CH A 1 CH A 1 AMP 2 CH A B 3 4 N L CH B 2 CH B 2 3 4 GND GND LKS 19 F 2 Section Pin LKS Pin out Solder side CH C 3 CH C 3 AMP 2 CH C D 1 6 L N CH D 4 CH D 4 1 6 GND GND AMP 3 CH A B C D CH A 1 CH A 1 AMP 3 CH A B C D 2 1 L N CH B 2 CH B 2 3 2 L N CH C 3 CH C 3 3 4 N L CH D 4 CH D 4 3 4 GND GND d b Z5330 050 Manual 1 1 en 9 ...

Page 10: ...losed rack link cable Z5333 Rack link Ethernet network ETH 1 Represents the upper etherCON connector of the first amplifier and may be used as input while the other two amplifiers are linked within the rack ETH 2 Represents the bottom etherCON connector of the last third amplifier and may be used as output Note In a daisy chain topology if one device or an entire rack fails or is switched off this...

Page 11: ...h allows two settings 1 LINK In system racks at the start of and within a CAN Bus segment set the switch to LINK 2 TERMINATE On the last system rack of a CAN Bus segment set the switch to TERMINATE Note A detailed description of remote control via the d b Remote network CAN Bus is given in the technical information TI 312 d b code D5312 EN which can be downloaded from the d b website at www dbaudi...

Page 12: ...N Bus networks Technical specifications Audio connector 2 x XLR female to 2 x XLR male with color markup Audio signal capability Analog Digital AES EBU AES 3 Network connector etherCON Network cable CAT 5E SFTP Length 2 m 6 5 ft Rack link example 4ch Digital audio and CAN Bus Rack link example 2ch Analog audio and CAN Bus 5 Z5333 Rack link d b Z5330 050 Manual 1 1 en 12 ...

Page 13: ...t to any later design or electromechanical modifications We herewith declare that said products are designed and tested in conformity with the provisions of the respective IEC 60065 directive including all applicable amendments EN 60065 2002 d b audiotechnik GmbH of Backnang accepts responsibility for this declaration Backnang 2014 05 19 Frank Bothe Head of R D d b audiotechnik GmbH 6 Manufacturer...