1.1. Scope of supply
Please verify the shipment for completeness and proper condition

of the items.

Qty.

d&b Code

Description

1

Z5442

Wall mount column 

[1] consisting

of:

Wall plate 

[1a]

Hinged bracket 

[1b]

Cabinet connecting plate 

[1c]

Note: Due to the size and easy

handling of the wall plate 

[1a], it

also serves as the fixing template.

Including:

4

 

Allen hex screw M6 x 12 

[2]

4

 

T-slot nut 8 mm / M6 

[3]

1

D2621.EN .01

Z5442 Mounting instructions

1.2. Safety precautions

General safety
Installation and setup should only be carried out by qualified and

authorized personnel observing the valid national Rules for the

Prevention of Accidents (RPA).

It is the responsibility of the person installing the assembly to ensure

that the suspension/fixing points are suitable for the intended use.

Always carry out a visual and functional inspection of the items

before use. In case there is any doubt as to the proper functioning

and safety of the items, these must be withdrawn from use

immediately.

Load safety information

NOTICE!

Only use mounting parts (fixing anchors and screws) that are

suitable for the intended application.
Observe the occurring extraction forces acting on the fixing

anchors and screws. The rated extraction force is 

350 N.

The maximum permitted working load of the Z5442 Wall mount

column is 16 kg (35 lb), which corresponds to the weight of a

complete 24C/24C-E assembly.

1. Z5442 Wall mount column

 

d&b Z5442 Mounting instructions 1.1 en

4

Summary of Contents for Z5442

Page 1: ...Z5442 Mounting instructions 1 1 en Z ...

Page 2: ...ep these mountings instructions with the product or in a safe place so that they are available for future reference When reselling this product hand over these mounting instructions to the new customer d b audiotechnik GmbH Eugen Adolff Strasse 134 D 71522 Backnang Germany T 49 7191 9669 0 F 49 7191 95 00 00 docadmin dbaudio com www dbaudio com ...

Page 3: ...mn 4 1 1 Scope of supply 4 1 2 Safety precautions 4 1 3 Intended use 5 2 Assembly 6 3 Built in dimensions 9 4 Declarations 10 4 1 Manufacturer s declaration 10 4 2 Disposal 10 Contents d b Z5442 Mounting instructions 1 1 en 3 ...

Page 4: ...ccidents RPA It is the responsibility of the person installing the assembly to ensure that the suspension fixing points are suitable for the intended use Always carry out a visual and functional inspection of the items before use In case there is any doubt as to the proper functioning and safety of the items these must be withdrawn from use immediately Load safety information NOTICE Only use mount...

Page 5: ...e maximum downtilt of 15 the wall mount must be attached to the center of the 24C cabinet as shown in the graphic opposite 1 3 Intended use The d b Z5442 Wall mount column must only be used in conjunction with applicable d b column loudspeakers It is intended for direct wall mounting The eyelet S of the cabinet connecting plate is intended for attaching a secondary safety device if required Depend...

Page 6: ...nserted into the T slot profile and turned through 90 for final positioning Dismounting the wall plate 1a 1 Slacken and remove the self securing nut N 2 Remove the U washers U and the Allen hex screw A 3 Take off the wall plate Preparing the cabinet connecting plate 1c 1 Insert all Allen hex screws 2 into the connecting plate 1c 2 Fit the T slot nuts 3 to the screws and turn the nuts 3 4 times 2 A...

Page 7: ...ame manner Attaching the cabinet to the wall plate 1a Provided you have mounted the wall plate in the desired position on the wall proceed as follows 1 Attach the cabinet to the wall plate as shown in the graphic opposite 2 Insert the Allen hex screw A and attach the U washers U and the self securing nut N 3 Slightly tighten the nut 4 Set your desired horizontal aiming 5 Finally tighten the nut to...

Page 8: ...lacken the stop screw B 2 While a second person secures the cabinet slightly slacken the fixing bolt F 3 Set the desired vertical downtilt 4 Adjust the stop screw B until the desired angle is finally set 5 Tighten the counter nut C to fix the adjustment 6 Retighten the fixing bolt F d b Z5442 Mounting instructions 1 1 en 8 ...

Page 9: ...d 24C columns total height of 24C with 24C E extender maximum depth and distance to the wall Built in dimensions at 15 downtilt in mm inch From left Total height and depth of single 16C and 24C columns and 24C with 24C E extender 3 Built in dimensions d b Z5442 Mounting instructions 1 1 en 9 ...

Page 10: ...55 BGV C1 Backnang 2014 02 04 Frank Bothe Head of R D d b audiotechnik GmbH 4 2 Disposal When out of use the rigging components must be disposed of in accordance with the national environmental regulations Ensure that damaged rigging components are disposed of in a way that they cannot be used again 4 Declarations d b Z5442 Mounting instructions 1 1 en 10 ...