background image

 

CAN-Bus network

CAN

Represents the CAN input of the first amplifier

while the other amplifiers are linked within the

rack.

CAN LINK

Represents the CAN output of the last

amplifier.

TERMINATE/

LINK

The built-in termination switch allows two

settings:
1.

LINK: In system racks, at the start of and

within a CAN-Bus segment, set the switch

to LINK.

2.

TERMINATE: On the last system rack of

a CAN-Bus segment, set the switch to

TERMINATE

Note: A detailed description of remote control via the d&b

Remote network (CAN-Bus) is given in the technical

information TI 312 (d&b code D5312.EN) which can be

downloaded from the d&b website at 

www.dbaudio.com

.

5.3. Z5333 Rack Link
The rack link cable allows multiple system racks to be linked

together.

It is suitable for both analog and digital audio signals as well as

for network wiring (Ethernet or CAN-Bus networks).

Technical specifications

Audio connector

2 x XLR female to 2 x XLR male

with color markup

Audio signal capability

Analog

Digital AES3

Network connector

etherCON

Network cable

CAT 5E STP

Length

2 m / 6.5 ft

I/O panel, rack link example:
2ch Analog audio and CAN

 

d&b Z5576.050 Manual 1.1 en

15

Summary of Contents for Z5576.050

Page 1: ...D Z5576 050 Manual 1 1 en ...

Page 2: ...e d b website for the latest version of this manual When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the systems If you require additional manuals for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Str 134 D 71522 Backnang Germany T ...

Page 3: ...Front panel 8 3 2 1 MAINS IN 8 3 3 Rear panel 9 3 3 1 AUXILIARY MAINS OUTPUTS 9 4 Z5578 LS connector panel 6 x NL8 2 x LKA25 10 4 1 Intended use 10 4 2 ETH POE INCLINOMETER 10 4 3 4 CH OUTPUTS 11 4 4 12 CH OUTPUT 11 5 DS10 and I O panel 13 5 1 DS10 configurations 13 5 2 I O panel 14 5 2 1 INPUT section 14 5 2 2 INPUT LINK section 14 5 2 3 REMOTE section 14 5 3 Z5333 Rack Link 15 6 Rack wiring diag...

Page 4: ...oudspeaker connector panel Z5578 In addition the Z5578 loudspeaker connector panel incorporates a POE Power Over Ethernet enabled etherCON RJ 45 connector for the direct connection of an inclinometer Also incorporated is an I O panel Z5338 which serves as a connector interface for both analog and digital audio signals as well as four network connectors for either Ethernet or CAN Bus remote capabil...

Page 5: ...19 frame Including 2 1 Z5577 001 Mains power distributor 2 x 30 A NEMA 3 1 Z5578 000 LS Connector panel 2 x LKA 25 6 x NL8 4 6 Z2710 D80 Amplifier 5 1 Z5338 I O Panel 6 1 Z4010 DS10 Audio Network Bridge 7 1 E8106 POE Power Over Ethernet injector device Mounted at the top left rear of the rack assembly 8 1 Z5333 Rack link cable 8 D2029 US 01 Z5576 050 Manual To be ordered separately Dimensions and ...

Page 6: ... rack to ensure adequate cooling airflow Make sure both the front and rear doors are opened and pushed into their park position to provide sufficient cooling Do not stack Z5576 050 Touring rack assemblies The rack assemblies can be positioned side by side They can also be combined with Z5330 D80 or Z5560 D20 Touring rack assemblies either side by side or with a maximum of one of these Touring rack...

Page 7: ... rack assembly that produces an opposing airflow observe the following restrictions Do not stack D12 Touring racks or any other rack assemblies with opposing airflow on top of the Z5576 050 Touring rack Z5576 050 D12 Touring rack assemblies can be positioned side by side d b Z5576 050 Manual 1 1 en 7 ...

Page 8: ...it before further use Do not connect or disconnect the NEMA mains connector under load or live Please ensure the NEMA mains connector is properly connected and locked Please ensure the mains connector is accessible at any time to disconnect the unit in case of malfunction or danger The Z5577 001 Mains power distributor is supplied with two NEMA 30 A 3ØY 120 208 VAC male connector socket that excep...

Page 9: ... are used to apply mains supply for the DS10 and the POE injector device The remaining sockets are intended for the connection of low current devices such as notebooks or additional Ethernet switches The sockets are equipped with dedicated circuit breakers 16 A C type Please refer to the assignment as shown in the graphic opposite d b Z5576 050 Manual 1 1 en 9 ...

Page 10: ...to feed an inclinometer which is integrated in the flying frame for vertical aiming of the entire array E8106 POE Injector device In connection with the ETH POE INCLINOMETER socket a corresponding IEEE802 3af compliant and prewired POE Injector device is mounted at the top left rear of the rack assembly The device features an LED indicator providing the following status information Solid green Val...

Page 11: ...t system wiring using the d b MC24 multicore system Z5328 xxx MC24 LKA25 F M Multicore Z5325 000 Break out adapterLKA25M to 6 x NLT4M Z5327 000 Break out adapter LKA25M to 12 x NLT4M and Z5326 000 Break in adapter 3 x NLT8F to LKA25F The d b MC24 Multicore System combines a 12 amplification channels 24 lines 4 mm2 cable with an LKA25 F M connector For this reason each connector of the loudspeaker ...

Page 12: ... NL8 Amplifier A 1 AMP 1 A 1 AMP 4 B 1 B 1 C 2 C 2 D 2 D 2 E 3 E 3 F 3 F 3 G 4 G 4 H 4 H 4 I 1 AMP 2 I 1 AMP 5 J 1 J 1 K 2 K 2 L 2 L 2 M 3 M 3 N 3 N 3 O 4 O 4 P 4 P 4 Q 1 AMP 3 Q 1 AMP 6 R 1 R 1 T 2 T 2 U 2 U 2 V 3 V 3 W 3 W 3 X 4 X 4 Y 4 Y 4 d b Z5576 050 Manual 1 1 en 12 ...

Page 13: ...to provide access to the amplifiers The DS10 in combination with the I O panel allows various configurations Two recommended configurations are detailed below Note For detailed information on how to configure the DS10 please refer to the DS10 manual which can be downloaded from the d b product page at www dbaudio com Ensure the BYPASS NETWORK switch of the DS10 is set to NETWORK PRI OCA on separat...

Page 14: ...EMOTE section The REMOTE section allows the daisy chaining of rack assemblies within a remote network using the enclosed rack link cable Z5333 Rack Link For detailed specifications please refer to the following sections Þ Ethernet network Þ CAN Bus network I O panel rack link example 2ch Analog audio and Ethernet OCA DS10 mode Redundant VLAN Ethernet network For remote purposes via Ethernet OCA it...

Page 15: ...ontrol via the d b Remote network CAN Bus is given in the technical information TI 312 d b code D5312 EN which can be downloaded from the d b website at www dbaudio com 5 3 Z5333 Rack Link The rack link cable allows multiple system racks to be linked together It is suitable for both analog and digital audio signals as well as for network wiring Ethernet or CAN Bus networks Technical specifications...

Page 16: ...Mains power connection and internal mains supply distribution 6 Rack wiring diagrams d b Z5576 050 Manual 1 1 en 16 ...

Page 17: ...Internal 4 CHANNEL OUTPUT wiring d b Z5576 050 Manual 1 1 en 17 ...

Page 18: ...Internal audio INPUT and LINK wiring d b Z5576 050 Manual 1 1 en 18 ...

Page 19: ...Internal Ethernet wiring and POE injection d b Z5576 050 Manual 1 1 en 19 ...

Page 20: ...Internal CAN Bus wiring d b Z5576 050 Manual 1 1 en 20 ...

Page 21: ......

Page 22: ...D2029 US 01 04 2018 d b audiotechnik GmbH www dbaudio com ...

Reviews: