background image

Q-SUB

Fig. 1: Q-SUB

The Q-SUB is the subwoofer for the Q-Series. It can be used to
supplement Q1 and Q7 cabinets in various combinations, either flown
or ground stacked. The Q-SUB cabinet is an actively driven bass-reflex
design housing a long excursion 18“ driver, its frequency response
extending from 40 Hz to 130 Hz.

The Q-SUB cabinet is constructed from marine plywood and has an
impact resistant paint finish. The front of the loudspeaker cabinet is
protected by a rigid metal grill, covered with a replaceable acoustically
transparent foam. The cabinet incorporates a pair of handles, and
mounted on the rear panel are two EP5 or NL4 connectors wired in
parallel and four heavy duty wheels. An M20 threaded flange in the top
panel accepts the d&b Z5013 Loudspeaker stand for the deployment of
full range cabinets.

The Q-SUB has a total of 10 sockets in the front grill and side panels to
accept the Z5153 Locking pins 8 mm that connect to the array links of
the Q1 system. Two runners extend from the rear to the front panel of
the cabinet protecting the bottom panel against scratching. Two
correspondingly shaped recesses are incorporated in the top panel of
each cabinet that accept these runners to prevent cabinet movement
when stacking Q-SUBs.

CAUTION!

Only operate Q-SUB loudspeakers with a d&b amplifier configured for
the Q-SUB otherwise there is a risk of damage to the loudspeaker
components.

Connections

1
2
3
4
5

1
2
3
4
5

Sense Drive

n.c.

Fig. 2: Connector wiring

The Q-SUB cabinet is fitted with a pair of EP5 connectors. All five pins of
both connectors are wired in parallel. The Q-SUB uses the pin
assignments 3/4 and 5. Pin 5 is used for SenseDrive (only available
when using a D12 amplifier and 5-wire cabling). Pins 1/2 are designated
to Q-Series full range systems. Using the male connector as the input,
the female connector allows for direct connection to additional
loudspeakers.

The Q-SUB can be supplied with NL4 output connectors as an option.
The D12 SenseDrive function is not available when using NL4
connectors. Pin equivalents of EP5 and NL4 connectors are listed in the
table below.

EP5

1

2

3

4

5  (SenseDrive)

NL4

1+

1−

2+

2−

n.a.

Tab. 1: EP5 and NL4 pin assignments

Operation with D12

IMPORTANT!

Selecting Q-SUB mode in the D12 enables up to two Q-SUB subwoofers
to be driven by the respective channel. In applications with low
continuous levels or low ambient temperatures up to three subwoofers
per channel can be connected.

Controller settings

100 Hz circuit

If the 100 Hz circuit is selected, the upper operating frequency of the
system is reduced from 130 Hz to 100 Hz.

Q-SUB Manual

(2.1E)    

Page 4 of 8

Summary of Contents for Q-SUB

Page 1: ...Q SUB Manual 2 1E ...

Page 2: ... The information contained in this manual has been carefully checked for accuracy at the time of going to press however no guarantee is given with respect to the correctness d b audiotechnik AG accepts no responsibility for any errors or inaccuracies that may appear in this manual or the products and software described in it Technical specifications dimensions weights and properties do not represe...

Page 3: ... one another use straps to secure them against movement Only use accessories which have been tested and approved by d b for assembly and mobile deployment Pay attention to the correct application and maximum load capacity of the accessories as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used fo...

Page 4: ...ent cabinet movement when stacking Q SUBs CAUTION Only operate Q SUB loudspeakers with a d b amplifier configured for the Q SUB otherwise there is a risk of damage to the loudspeaker components Connections 1 2 3 4 5 1 2 3 4 5 Sense Drive n c Fig 2 Connector wiring The Q SUB cabinet is fitted with a pair of EP5 connectors All five pins of both connectors are wired in parallel The Q SUB uses the pin...

Page 5: ... input level to the loudspeakers results in no gain in acoustical output The 100 Hz setting is available The characteristics of the 100 Hz setting is explained under the previous section Operation with D12 Controller settings Technical specifications Fig 4 Q SUB frequency response standard and 100 Hz settings Q SUB system data Frequency response 5 dB standard 40 Hz 130 Hz Frequency response 5 dB 1...

Page 6: ...e side panels of the Q SUB cabinet is an additional socket that enables the Q1 cabinet to be tilted downwards up to 6 for ground stacked use In this case the Z5152 Q Front links have to be rotated through 180 before attaching to allow the Q1 cabinet to be tilted to the front see picture below 180 Fig 9 Orientation of Z5152 Q Front links Q SUB and Q7 cabinets An M20 threaded flange in the top panel...

Page 7: ...d provided they correspond to the original technical version and have not been subject to any later design or electromechanical modifications We herewith declare that said products are in conformity with the provisions of the following EC directives including all applicable amendments 89 336 Electromagnetic Compatibility The following standards have been applied DIN EN 55013 08 1991 DIN EN 55020 0...

Page 8: ...D2042 E 02 11 2004 d b audiotechnik AG d b audiotechnik AG Eugen Adolff Str 134 D 71522 Backnang Germany Phone 49 7191 9669 0 Fax 49 7191 95 00 00_______ ...

Reviews: