background image

https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad

Result

: All User Codes will have been deleted, the Sub-Master and Technician Codes disabled and all settings reverted to factory

default. The Master Code will be 11335577 and a single User Code of 2244 will be available. The lock will be in Private Function. 

Firmware Check 

 

To check the firmware version installed on the lock. 

#Master Code 

● 

88 

 

 

Example

: #11335577 

 88 

 

 

Result

: The LED will flash to indicate firmware version (e.g. 

 Red LED flash once and 

 Blue LED flash twice, firmware version is

12). User can wait 30 seconds to exit or can press ‘0’ button to exit and return to normal mode. 

Summary of Contents for CodeLocks KL1100

Page 1: ...ts Sub Master Code Client 8 digits Technician Code Client 6 digits User Code Clients 4 digits Functions Operating Instructions Change the Master Code Private Public Function Set or Change the User Cod...

Page 2: ...re any further use is possible Batteries The KL1100 Keypad uses 4 x AA batteries Always use high quality batteries and dispose of old batteries according to local authority recommendations When batter...

Page 3: ...4 Important Once a Master Code Client is registered it should be kept in a safe location The Master Code is required for all programming operations Functions Before programming select the most appropr...

Page 4: ...ple 11335577 02 01 7788 Result The User Code in position 01 has been set to 7788 Note Up to 20 User Codes can be created Each User is entered at a single known position Delete a User Code Private Func...

Page 5: ...ot automatically unlock and will remain locked until User Master Sub Master Code entered Auto Unlock At a Set Time Public Function Master Code 11 HHmm Example 11335577 11 2000 Result The lock will aut...

Page 6: ...s been disabled Note By default locked indication is enabled the red LED will flash once every 5 seconds to indicate a locked lock Set or Change Technician Code Private Public Function Master Code Or...

Page 7: ...e 26 Example The lock will operate in Private Use remaining locked unless opened by a valid code Any User Codes in position 02 to 20 will erased A default User Code of 2244 will be active in position...

Page 8: ...n unlocked state open the cabinet and replace the batteries found in the latch unit Factory Reset Master Code Unknown If the Master Code has been forgotten the manual method must be used Keypad Method...

Page 9: ...ll be 11335577 and a single User Code of 2244 will be available The lock will be in Private Function Firmware Check To check the firmware version installed on the lock Master Code 88 Example 11335577...