59
Supplement 1 Notes to function mapping
If you want to activate a function enter the value of the corresponding output according to the following table. In case
you want to activate several different functions simultanously you must add up the related values.
Output values:
RG / AUX6
ABL / AUX5
AUX4
AUX3
AUX2
AUX1
LR
LV
Value
128
64
32
16
8
4
2
1
RG = shunting gear
ABL = dimmed headlight
Example:
F4 should activate the shunting gear and switch on the outputs LV and LR:
LV=1, LR=2, RG=128: so you must enter the value 131 in CV38 | par066.
Notice:
AUX3 and AUX4 are not available in all decoders as amplified ones, however always alternatively
available to ZCLK and ZDAT as unampliefied ones.
AUX5 and AUX6 are not in all decoders available (generally only unamplified), however always
alternatively available to ZCLK and ZDATas unamplified ones.
Timer function
(CV117
– 120, 129, 130 / par076 – 079, 145, 146)
Value = 0
The timer is switched off (continuous function)
Value
= 1…250
The timer is activated, the coressponding output will be disconnected after the time of: entered
value x 0.1 [sec].
Summary of Contents for DH05C