Part NO: 212-0024WB
15
July 30th, 2019
Specifications
General
Description
No. of Available Connections
Power Inputs:
6 AWG +12V @ 60A max input current
1
6 AWG Ground
1
18 AWG Ignition Control Input
1
Power Output (High Current Connection)
8 AWG @ 30A Max +12V (fused at 50A)
1
8 AWG Ground
1
Battery Voltage Monitor
18 AWG sense wire @ +12V BATT terminal
1
18 AWG sense wire @ GND BATT terminal
1
Terminal Block Power Outputs
Ignition Controlled Power - 70A relay the total current not to exceed 40A
6
Continuous Power - the total current not to exceed 60A
6
Timed Power - the total current not to exceed 60A
6
Ground return path for the Output terminal blocks the total return current not
exceed 60A
5
NOTE:
All combined output power (using any combination of outputs) not
to exceed 60A
Timed Outputs With Voltage Protection
Specification
Operating Voltage (monitored/allowed by protection feature)
11.5V—18V
Stand-by Current
30mA
Operating Current
600mA
Selectable Time Delay
2 min. - 13 hrs.
Input Voltage Low Sensing Threshold
>14.0V
Input Voltage Low Disconnect
<11.5V
Input Voltage High Disconnect
>18.0V