Part#:212-0042 9
July 31, 2019
Arrow Stick with Master
-
When the Arrow Stick (AS) is activated by the master switch only
one preset pattern will be displayed, the factory default is the “CENTER OUT” pattern, if one of
the other 6 patterns is desired this must be programmed separately.
These patterns can be programmed into the individual Slide Switch master modes;
* AS on SS1 press and hold SW3+SW7
** AS on SS2 press and hold SW4+SW7
***AS on SS3 press and hold SW5+SW7
1) Entering the setup mode press and hold the indicated keys and wait for the 2 beeps
2) Select the arrow stick pattern from table 3 below.
3)
The 3 LED’s above SW16 will show the pattern selected from Table 3.
Save the
configuration; press and hold SW9 (STBY/PA) until the long beep, this confirms the program
is saved.
Arrowstick Modes:
-
When ARROWSTICK is enabled the RDS17S has two modes of arrowstick control:
CODE3 system (default)
- this mode it is a
data control only
arrowstick and it needs a D&R traffic
director or a D&R digital to analog convertor box in order to control standard ground controlled traffic direc-
tors. Using SW16 the following patterns can be activated: LEFT ARROW, RIGHT ARROW, CENTER OUT,
CENTER FLASH, ALTERNATE LEFT-RIGHT, RANDOM FLASH.
911 system
- in this mode the RDS17S uses OUT13 and OUT14 for traffic director control. Using
SW16 the following functions can be activated: LEFT ARROW (OUT13), RIGHT ARROW (OUT 14),
CENTER OUT (OUT13 & OUT14).
Pattern
SWITCH
SWITCH SETTING only one at a time can be ON
LEFT ARROW
SW10
ON
off
off
off
off
off
RIGHT ARROW
SW11
off
ON
off
off
off
off
CENTER OUT
SW12
off
off
ON
off
off
off
CENTER FLASH
SW13
off
off
off
ON
off
off
ALTERNATE LEFT & RIGHT
SW14
off
off
off
off
ON
off
RANDOM BAR FLASH
SW15
off
off
off
off
off
ON
Figure 5- Programming Arrow Stick