Installing/Servicing the Airlab
Airlab from D&R Phone +31 294 418014, email:
info@d-r.nl
Page
47
9.
Move the TELCO modules fader to its 0 dB position. Press the ON switch and activate the
PROG and SUB switch
only. The LINE IN switch should be off (up).
10.
CHECK if the CRM outputs this PHONE IN signal coming from the PROG buss, (No CRM
select switches are active) to be sure that you have correctly connected and routed your
source.
11.
Now open the fader on the channel where you have connected your audio and Press the ON
switch on that channel.
12.
Now you shall hear the audio signal through the TELCO module that is fed from that channel.
13.
Now adjust the front panel trimmer VR1 (labeled R-BAL) to a minimum audio position and look
for the best combination of C jumper settings and trimmer position.
14.
Power down the console and install the module again properly.
As long as the hybrid remains connected to the same "Phone Company", no changes need to be made to
this setup. If more TELCO modules need to be aligned the same capacitor value shall be used for all
modules so front panel trimming is the only trimming that is left to do for the other modules.
Try to by-pass the in house telephone system if possible. Otherwise it will be extremely difficult to achieve
a good alignment. A direct connection with the incoming phone company gives best results.
NOTE: INSTALLATION OF NEW (EXTRA) MODULES
When installing new (extra) modules in your Airlab it's necessary to re-adjust the internal power supply
voltages to guarantee a stable performance at all times.
More current is taken from the internal power supply because you have put in more modules now. It's
necessary to adjust the power supply voltage to a precise level of 18 volts for both the positive and
negative rails with all modules connected.
Adjustment is performed on the power supply PCB mounted on the bottom of the console located beneath
the master section.
Power supply voltage is measured across the output terminals of the power supply PCB inside the console.
NOTE: If the power supply voltage is not adjusted to 18 volts again, it may be possible that
certain logic functions may not work properly at all times.
Summary of Contents for Airlab
Page 77: ...Airlab sch 1 Fri Aug 20 14 30 15 1999 ...
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ...Airlb20p sch 1 Thu Feb 07 13 52 55 2002 ...
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 95: ......
Page 96: ...airlb8p sch 1 Thu Feb 07 13 09 57 2002 ...
Page 97: ...airlb8p sch 1 Thu Feb 07 13 09 03 2002 ...
Page 98: ...Airlb7p sch 1 Fri Aug 20 15 09 31 1999 ...
Page 100: ......
Page 103: ......
Page 106: ......
Page 109: ... 10350776 Weerstand 10MO 5 1 4W 11 0000 st ...
Page 111: ...DigAudioIO_a sch 1 Wed Nov 22 11 08 39 2006 ...
Page 115: ......