Function Name
Comments
Object to connect to
Version
Console preset 20
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.1
Console preset 21
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.1
Console preset 22
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.1
Console preset 23
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.1
Console preset 24
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.1
Console preset 25
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.1
Console preset 26
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.1
Console preset 27
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.1
Console preset 28
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.1
Console preset 29
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.0
Console preset 30
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.0
Console preset 31
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.0
Console preset 32
After one second recalls the preset on-air safe.
After three seconds it forces the on-air channels to
recall.
Switch
2.0
Initialization status
This function gives information on the Initialization
status used by progress bars that may be displayed at
boot time.
Progress bar
2.5
20.6 Sources
Some objects have functionalities that relate to the source selected on a module. For example if you
have a GPI that needs to trigger a CUE or Alert module function. In addition, a GPO can have a
relation to the fader on/off of the module where its source is connected.
This group with source functions makes it possible to have source related module functionality:
Name
comments
Example
object to
connect to
Version
Module on
connect to the module(s) on if this source is selected
GPIO
2.0
Module off
connect to the module(s) off if this source is selected
GPIO
2.0
Module on/off
connect to the module(s) on/off if this source is selected
GPIO
2.0
Module fader on
connect to the module(s) fader on if this source is selected
GPIO
2.0
Module fader off
connect to the module(s) fader off this source is selected
GPIO
2.0
Module fader on/off
connect to the module(s) fader on/off this source is selected
GPIO
2.0
Module fader and on active
connect to the module(s) fader on and on if this source is selected
GPIO
2.0
Module fader and on
inactive
connect to the module(s) fader on and on if this source is selected
GPIO
2.0
Module fader and on
active/inactive
connect to the module(s) fader on and on if this source is selected
GPIO
2.2
Module buss 1/2 on
connect to the module(s) buss 1/2 on if this source is selected
GPIO
2.0
Module buss 1/2 off
connect to the module(s) buss 1/2 off if this source is selected
GPIO
2.0
Module buss 1/2 on/off
connect to the module(s) buss 1/2 on/off if this source is selected
GPIO
2.0
Module buss 3/4 on
connect to the module(s) buss 3/4 on if this source is selected
GPIO
2.0