A
·
X
·
U
·
M User Manual
Version 2.5 - 2011-01-28
AXUM from D&R - Phone: +31 294 418014 - E-Mail:
info@d-r.nl
- 21 -
6.1.4
Monitor buss configuration
Per DSP card, you have 4 stereo monitor busses that can be used. They need a name, console
assignment and configuration so they can work properly:
Figure 9: Monitor buss configuration
•
Label
Here you give a name to this monitor buss
•
Interlock
Yes means only one source is active at the same time, on this monitor buss.
•
Default selection
If the last selected source is turned off it will always go to the default selection.
This selection is also your startup default.
•
Automatic switching
.
You can tell the Engine that a monitor buss switches automatically when the ‘source buss’ is
activated. Also known as ‘PFL to CRM’. If you have two separate studios’ you can have
multiple automatically switched busses (e.g. PFL 1 and PFL 2).
When to mix buss is an exclusive buss, the monitor buss will also switch ‘exclusive’; normally
automatic switching will be summing with the set up ‘Dim level’.
•
Dim level
When you have set the monitor buss to switch automatically, the source signal is dimmed by
the filled in level and the buss that is switched on to the Monitor buss is at unity gain (0 dB).
•
Console
You can select to which console a monitor buss belongs.