11.2 Wiring
11.2.1 GPIO/Remote
The remote jack connects to all kinds of remote in-/outputs. Such as remote start/stop, external red
lights or cough. The function of the remote jack depends on the I/O card and function setup for this
GPIO. The software determines its function and where it is connected to.
! NEVER CONNECT HIGH POWER VOLTAGE (WALL POWER) TO THE REMOTE-JACK !
If the GPIO jumper setting on the Axum-Rack-Board is set for GPO the remote becomes only a
Remote-Output by a build in Solid State Relay. The relay is situated between Tip and Ring of the
remote jack.
Normally the GPIO jumper setting on the Axum-Rack-boards are set for GPO.
Jack
Name
function
Comment
Tip
GP-CC
GPIO Jumper 23 & 56:
Photo MOS relay (max 50V, 200mA)
Ring
GP-NO
Sleeve Shield
Ground
Table : GPO Patch Panel wiring
If the GPIO jumper setting on the Axum-rack-Board is set for GPIO the remote becomes a Remote-
Output GPO (+5V TTL) on the Tip of the remote jack and a Remote-Input GPI (+5V TTL internal pull-
up) on the Ring. The Sleeve is Shield and the ground for the TTL signal.
Jack
Name
function
Comment
Tip
GP-Output
GPIO Jumper 12 & 45:
GPO: +5V, 560R Ohm
GPI:
max. +5V with 10k internal pull-up.
Ring
GP-Input
Sleeve Shield
Ground
Table : GPIO Patch Panel wiring