Operator's Manual for DM100 VDR and DM100 S-VDR G2
Copyright Danelec Marine A/S
710
|CAPSULE
The
amount
of
data
received
by the VDR exceeds the capacity
of
Record-data
too
big
|
the
fixed
capsule.
This
is
typically
caused by
receipt
of
too
much
image data. Use the “Analysis
of
recorded
data”
utility
on the BCP
or in
the
configurator
tool
to determine
the
cause.
If
the
problem
relates
to
image data, carry out an OPT and check the recorded
images.
711
|Capsule
The DPU has detected a too high data loss rate (saving
to
the fixed
hey
loss rate
too
|
capsule) over a period
of
time. The most likely
cause
is
communication problems. Check the cable from
the
DPU to the
fixed capsule.
721
|
FLOAT-FREE
The
VDR
is
unable to record data to the float-free capsule.
Another
Not.
zecording
error
explaining
why
(e.g. #722 FLOAT-FREE
Cannot
find)
is
normally displayed in advance. Try to fix the
preceding
error,
otherwise reboot the system.
722
|FLOAT-FREE
The VDR is unable
to
detect the float-free capsule. Check
that
the
Cangoti
iting
float-free capsule is connected correctly.
If
the
error
persists, the
float-free capsule is
probably
defective.
723
|FLOAT-FREE
The
VDR
has detected a float-free capsule but
is
unable
to get
Cannot,
Access
access to the memory.
If
the error persists,
the
float-free capsule
is
probably
defective.
724
|FLOAT-FREE,
too
many
|Too
many write-errors (writing
to
the float-free capsule) have been
MILES
RrroLs
detected by the DPU
over
a
period
of
time. The most likely cause
is
communication problems. Check the cable from the DPU to the
float-free capsule.
725
|FLOAT-FREE,
too
many
|Too
many write-errors (writing to the FRM memory)
have
been
WEEE: SRFORS
detected by the float-free capsule over
a
period
of
time. The
most
likely cause is serious communication problems or a defective
float-free capsule.
726
|FLOAT-FREE,
too
many
|Too
many read-errors (reading
back
data from the float-free
EpadnsrIons
capsule) have been detected by the DPU
over
a
period
of
time. The
VDR was unable
to
write and verify data despite several attempts.
The
most
likely cause
is
serious communication
problems
or
a
defective float-free capsule.
727
|FLOAT-FREE,
too
many
|Too
many read-errors (reading
back
from the memory)
have
been
ready
errors
detected by the float-free capsule over a
period
of
time. The VDR
was unable to read
back
data despite several attempts. The
most
likely cause is serious communication problems or a defective
float-free capsule.
728
|
FLOAT-FREE
}
The VDR found too many data errors within a given interval when
Verification
failed
|yerifvino the data written to the float-free capsule.
729
|FLOAT-FREE
The amount
of
data collected for a 15-second period exceeds
the
Record
too big
maximum allowed size for the float-free capsule.
This
is
typically
caused
by
receipt
of
too much image data. Use the “Analysis
of
recorded
data”
utility
on the BCP or in the
configurator
tool
to
determine
the
cause.
If
the problem
relates
to image data, carry out
an OPT and check
the
recorded images.
DBS11011-20