2.1.4 Fixed capsule
The fixed data capsule (“the orange box”) must be installed on an “external deck close to the
vessels center line” - typically on the external deck above the bridge.
2.1.5 Float-free capsule
The float-free capsule is an additional data capsule which is required according to IEC 61996-1
ed2.0. It must be installed in the same way as an EPIRP.
2.1.6 Remote Video Interface (RVI)
The RVI is optional equipment. An RVI may be used to capture video from, for example, a
RADAR which is unable to send images to the VDR using Ethernet; i.e. typically older equipment.
The RVI must be installed indoors, normally close to the RADARs. It must be connected to the
DAU with a cable which may be up to 100m in length.
2.1.7 Sensor Interface Unit (SIU)
The SIU is optional equipment. An SIU is needed if, for example, door status cannot be provided
using a serial or Ethernet interface on the VDR.
A standard non-modular compact SIU has 8 serial interfaces, 8 analog interfaces and 64 digital
interfaces. A modular SIU also exists which can be configured to have other combinations of
interfaces. The SIU must be installed indoors. It must be connected to the DAU with an Ethernet
cable up to 100m long.
DBS11011-12
Page 7/27