This instruction sheet is for the field installation of the USB extension cable into the door 
of F-Frame VLT frequency converters.  

Note: This kit is applicable to drives built dur-

ing or after Week 40 of 2008. 

 Frequency converters built prior to Week 40, 2008 do not 

have the provisions for this kit. 
 

INSTRUCTIONS 

INSTALLATION OF USB EXTENSION CABLE INTO F-FRAME VLT

®

 DRIVES 

Instruction No: 177R0091 V0  Jan 2009    Page 1 

VLT

®

 is a registered trademark of Danfoss A/S 

Kit Contents 

• 

USB extension cord 

• 

Tie wraps 

• 

Instruction Sheet 177R0091 

Kit Part Number 

176F1784 

The door on the rectifier section of 
F-Frame VLTs are fitted with a 
feed-through hole to accommodate 
a USB extension cord so that the 
controls can be accessed from a 
laptop computer without requiring 
access to the inside of the VLT. 
 
With the rectifier door open, the 
hole is located near the upper right 
corner of the door.  See Figures 1 
and 2. 
 
The feed-through hole is covered 
by the decorative label on the out-
side and with a round sticker on the 
outside. 
 
 
 
 
 
 
 
 
 
 

Figure 1.  Location of USB feed-through hole. 

WARNING 

The frequency converter contains dangerous voltage.  Disconnect power and follow lock-
out/tag-out procedures before working on this equipment. 

Summary of Contents for 176F1784

Page 1: ...s Instruction Sheet 177R0091 Kit Part Number 176F1784 The door on the rectifier section of F Frame VLTs are fitted with a feed through hole to accommodate a USB extension cord so that the controls can be accessed from a laptop computer without requiring access to the inside of the VLT With the rectifier door open the hole is located near the upper right corner of the door See Figures 1 and 2 The f...

Page 2: ...creating a hole in the label from the inside of the door then cut through the decorative label from the outside to prevent the decorative label from separating from the door Figure 3 USB connector retaining nut Figure 4 Inserting USB cable into feed through hole Figure 2 Location of USB feed through hole 3 Remove the retaining nut from the USB cable See Figure 3 4 Insert the USB cable into the doo...

Page 3: ...9 Page 3 5 Secure the USB connector onto the door by using the USB cable retaining nut from inside the door Tighten securely See Figures 5 and 6 Figure 5 Securing USB connector with retaining nut Figure 6 USB connector installed on door ...

Page 4: ...ure 8 Utilize cable ties to secure the USB cable to the LCP cable until the cable is inside the cable channel Figure 8 Routing of USB cable in rectifier cabinet 8 Route the USB cable from the cable channel to the control card as shown in Figure 9 Figure 9 USB cable 6 Remove the cable channel cover from the front of the cable chan nel to enable insertion of the USB cable See Figure 7 ...

Page 5: ...ct the USB cable to the control card as shown in Figure 10 10 Reinstall the cable channel cover as shown in Figure 11 The installation of the USB cable is now complete Figure 10 USB cable connected to control card Figure 11 Front cover of cable channel ...

Reviews: