7.2 Environmental Data
Ambient temperature during operation
5–45
°
C (41–113
°
F) without derating
45–60
°
C (113–140
°
F) with derating 1.5% per
°
C.
See derating curve in
Temperature during storage and transpor-
tation
Transport: -25
°
C to +65
°
C (-13
°
F to +149
°
F)
Storage: -25
°
C to +55
°
C (-13
°
F to 131
°
F)
Maximum altitude above sea level
1000 m (3280 ft) without derating
1000–4000 m (3280–13123 ft) with derating 5% per 1000 m (3280 ft)
Relative humidity
Humidity class F without condensation 5–85% - Class 3K3 (non-condensing) during operation
Resonance search
Base standard: DIN EN 600068-2-6
Test specification: 5 Hz, 150 Hz, 3 directions (0.5 g, 0.1 g, 0.5 g)
Sine vibration test
Base standard: DIN EN 600068-2-6
Test specification: 5–13.2 Hz, 150 Hz (2 mm (0.08 in) peak to peak 0.7 g)
Packaging
ISPM 15
Enclosure protection rating
IP20
Optional IP21/NEMA1 upgrade kits
Approvals
CE
The Low Voltage Directive
UL
1)
UL SCCR 100 kA
Standards
Radiated Immunity, IEC 61800-3, 2012 edition 2.1
Burst, EN 61000-4-4
Surge, EN 61000-4-5
ESD, EN 61000-4-2
Radiated Field-CM, IEC 61800-3, 2012 edition 2.1
PELV in accordance to EN 61800-5-1 for the temperature switches
Table 7.2 Environmental Data
1) UL only for 460 V/60 Hz and 600 V/60 Hz versions. UL listing card reference ID number: E134261
Load in %
110
100
90
80
70
60
40
45
50
55
60
Ambient temperature in °C
130BB603.11
Illustration 7.1 Temperature Derating Curve
Specifications
VLT
®
Advanced Harmonic Filter AHF 005/AHF 010
50
Danfoss A/S © 05/2019 All rights reserved.
MG80C602
7
7
Summary of Contents for AHF 010
Page 2: ......