Instructions
Akva Lux II VX2
12.0 Description of Akva Lux II VX variants
12.1 Akva Lux II VX2 (ECL 110)
Substation for indirect heating for single-family, semi-detatched and
terraced houses as well as flats. With one heating circuit for radiator or
floor heating and instantaneous domestic hot water heater. Designed
for wall-mounting with connections in top and bottom of substation.
The temperature for the heating circuit is controlled by a Danfoss
ECL 110 controller in combination with an electronic actuator. The
supply temperature is calculated by the controller on basis of the
outdoor temperature.
Please note:
Your substation may look different than the substation shown, as vari-
ants with other components may be supplied.
Instructions for the fitted components will always be supplied to-
gether with the substation.
Heating circuit
The temperature for the heating circuit is controlled electronically
by the Danfoss ECL controller. The supply temperature is calculated
by the controller on basis of the outdoor temperature.
The factory-setting of the controller ensures that heating is automati-
cally switched off in the summer period.
In periods with higher heat demand the controller settings can be
changed in accordance with the enclosed producer instructions for
the mounted controller.
Installation & Maintenance
Danfoss ECL Comfort 110
Control of heating circuit
For controlling the heating circuit the Akva Lux II VX 2 (ECL 110) is
supplied with a 2-way valve VS 2 and an electrical actuator AMV 150,
which in combination with the ECL controller controls the heating
circuit.
The electrical actuator has undergone a functional test from factory.
In case of operating disturbances the actuator can be closed manu-
ally turning the manual override knob on top of actuator counter-
clockwise.
Please see enclosed instructions,
Electrical actuator AMV 150
2-way valve VS 2
DH-SMT/DK
VI.KT.F2.02 © Danfoss 06/2008
$2
!&4
Instructions
ECL Comfort 110
Application 116
Constant temperature control
of domestic hot-water systems (DHW)
User guide,
Installation & Maintenance
Manual override (AMV 150)
VS 2
Press and hold the button (on
the bottom side of the actuator)
during manual override.
7369267-9 SIBC R&D
EI.97.Q2.00 © Danfoss 12/01
1
INSTRUCTIONS
VS2 2-way
065R9075
065R9075
DN
L (mm)
15
65
20
70
25
75
DN
L
1
(mm)
15
131
20
142
25
159
DN
L
2
(mm)
15
139
20
154
25
159
DN
L
3
(mm)
15
69
20
74
25
79
Instructions
AMV 150
73691180 DH-SMT/SI
VI.KU.N2.1J © Danfoss 01/2008
1
ENglIsh
Actuators for three point control AMV 150
www.danfoss.com
Page 2
DANsK
Motorer til 3-punkts styring AMV 150
www.danfoss.dk
Side 3
DEUTsCh
Stellantriebe für 3-Pkt.- Eingangssignal AMV 150
www.danfoss.de
Seite 3
sVENsKA
Motor för 3-punktsreglering AMV 150
varme.danfoss.se
Sida 4
NEDERlANDs
Servomotor met 3-puntssturing AMV 150
www.danfoss.nl
Pagina 4
lIETUVIŲ K.
Pavaros trijų padėčių valdymui AMV 150
www.danfoss.lt
5 puslapis
lATVIsKI
Motori trīs punktu kontrolei AMV 150
www.danfoss.com
Lpp. 5
MAgYAR
Szelepmozgatók hárompontos szabályozáshoz AMV 150
www.danfoss.com
6. oldal
ČEsKY
Servopohony s tříbodovým regulačním signálem AMV 150
www.danfoss.cz
Strana 6
POlsKI
Siłowniki sterowane sygnałem 3-punktowym AMV 150
www.danfoss.pl
Strona 7
РУССКИЙ
Электроприводы для трехпозиционного регулирования AMV 150
www.danfoss.ru
Страница 7
AMV 150 +
AMV 150 +
AMV 150 +
VS2 (DN 15)
VMV
AVQM (DN 15)