Service guide
|
Disassembling and Assembling, APP(W) 5.1-10.2
© Danfoss | DCS (im) | 2017.06
8 | 180R9238 | DKCFN.PI.078.F3.02 | 521B1196
5. Change of shaft seal
1. Unscrew the seal retaining ring
counterclockwise and remove it.
Tools provided according to 180B4162
3. Carefully remove the flange from the
casing.
4. Wet the shaft and shaft seal with clean
filtered water.
2. Unscrew the 8 screws in the mounting
flange.
5. Carefully remove the shaft seal assembly
using the shaft-seal extractor supplied.
The extractor must fit underneath the
shaft seal.