Instruction
Disassembling and assembling APP S 674 2.0-3.5
20
180R9281 / 521B1275 / DKCFN.PI.013.C3.02 / 05.2013
7.
Replace the O-ring and mount the flange.
Ensure the guide pin is mounted.
8.
Mount two screws as shown below and
tighten them.
9.
Mount the remaining bolts and cross
tighten them to a torque of 30 Nm ± 3 Nm.
10. Connect the pump to the rest of the
system.
11. Bleed the pump before starting it.