Dimensions and connections
SV
DV
Suction line
Discharge line
see technical data, Chapter 8
A
Connection suction side, not lockable
1/8" NPTF
A1
Connection suction side, lockable
7/16" UNF
B
Connection discharge side, not lockable
1/8" NPTF
B1
Connection discharge side, lockable
7/16" UNF
C
Connection oil pressure safety switch OIL
1/8" NPTF
D
Connection oil pressure safety switch LP
1/8" NPTF
E
Connection oil pressure gauge
1/8" NPTF
F
Oil drain
1/4" NPTF
G
Opt. connection for oil sump heater
1)
H
Oil charge plug
1/4“ NPTF
K
Sight glass
2 x 1 1/8"- 18 UNEF
L
Connection thermal protection thermostat
1/8" NPTF
M
Oil strainer
M22 x 1.5
SV1
Opt. connection for suction line valve
- -
1)
No connection available as standard.
Available on request (Connection M22 x 1.5)