background image

CFRC REMOTE CONTROLLER

8

GB

5.2.1 Period program:

With this program, you can set the room temperature for all Room 
Thermostats during e.g. a holiday. The start and end date for the 
program is easily set in a calendar by means of the up/down and 
left/right selectors (fi g. 1-  / ) and by confi rming each setting with 
OK. The room temperature and the duration of the period program 
are illustrated and fi nally activated from a detailed overview for the 
created program:

5.2.2 Setback program:

In the 

Program setback

 menu, you have the opportunity to divide 

the diff erent rooms into up to six diff erent zones - each zone with up 
to three diff erent setback programs for reduced room temperature at 
diff erent times during the day.

Options:

Each zone has a screen showing the rooms included in the zone. This 
provides access to an 

Options

 menu with an 

Add Room

 function 

and three 

Setback programs

 (up to).

Add Room:

In this menu, all the rooms are followed by a ( ) indicating to what 
zone each room has been allocated (see fi gure below  ). As 

default

all the rooms are assigned to Zone 1. If new zones are created, the 
rooms will be moved from the zone to which they are allocated to the 
new zone (from zone 1 to zone 3 in the fi gure below).

Summary of Contents for CF-RC

Page 1: ...CF RC Remote Controller Installation and User Instruction MAKING MODERN LIVING POSSIBLE...

Page 2: ...0845 121 7400 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material All trademarks in this material are property of the respective companies Danf...

Page 3: ...nctional Overview 4 2 Installation 4 3 Transmission Test 5 4 Mounting 6 5 Menus 6 5 1 Rooms 6 5 2 Program 7 5 3 Setup 11 5 4 Alarms 13 6 Uninstallation 14 7 Other products for the CF2 system and abbre...

Page 4: ...vate Install mode by pressing OK The install LED goes ON 1 Functional Overview Front g 1 Display Soft key 1 Soft key 2 Up down selector Left right selector Icon for system alarm Icon for communication...

Page 5: ...spell menu to create other names When the installation is nished the start up screen will be shown in the display with the actual time and date on the top The screen also shows the actual temperature...

Page 6: ...the transmission range of the CF2 system up to three Repeater Units can be installed in a chain see g 4 5 Menus Note When the back light in the display is out the rst touch of a button only activates...

Page 7: ...t Change room name Here you can change the room names by means of a list of possible room names or you can use the spell menu to key in other names Set oor Min Max Here you can set and lock the minimu...

Page 8: ...ck menu you have the opportunity to divide the di erent rooms into up to six di erent zones each zone with up to three di erent setback programs for reduced room temperature at di erent times during t...

Page 9: ...1 f g to select the days for this program by moving them above the horizontal line Con rm with OK and activate the next step to select the time for the setback program Select the time for the setback...

Page 10: ...pitals Cancel program A created program can be deleted with the Cancel Program menu leading to the overview illustrated above Note In the Options menu the created programs 1 3 will be indicated by mor...

Page 11: ...ovides access to the setting of the date and time Furthermore this menu includes the settings for and activation of the summertime program This enables you to con gure at what day week and month the s...

Page 12: ...15 minutes In the Service menu activate the Standby temperature function with OK in order to set a xed room temperature for all the Room Thermostats to 5 35 C when the Global standby input is activate...

Page 13: ...of the Master Controller will go O if set to Sound On see chapter 5 3 and the CF2 system will switch to Alarm status as indicated on the start up screen This indication of Alarm on the Remote Control...

Page 14: ...e the Soft key 1 d the soft key 2 e6and the down selector f The Remote Controller requests con rmation before resetting Con rmation with yes Resets the Remote Controller By con rming Reset with yes th...

Page 15: ...om Thermostat in the indicated room has lost the wireless connection to the Master Controller MC Low battery in Room Thermostat E13 The battery level of the RoomThermostat for the indicated room is lo...

Page 16: ...CF RC REMOTE CONTROLLER 16 GB GB...

Page 17: ...Danfoss Heating 17 GB GB...

Page 18: ...CF RC REMOTE CONTROLLER 18 GB...

Page 19: ...Danfoss Heating 19 GB...

Page 20: ...Part No 90063v01 01 10 Danfoss Randall Ltd Ampthill Road Bedford MK42 9ER Tel 0845 1217 400 Fax 0845 1217 515 Email danfossrandall danfoss com Website www danfoss randall co uk...

Reviews: