EN
Drawing
Designation
Tools
85
- 85 large heat shrink tube is put
in over the end cable.
Now, put the 12/3 heat shrink tube
(Length = 85 mm) over the end of the cable
to the edge of the removed outer sheath.
22
- Approx. 22 mm large heat
shrink tube must stay on the
heating cable.
- The rest of the shrink tube is
squeezed while still hot.
Beginning at the end of the heat shrink
tube, shrink the tube at a temperature
275 °F / 135 °C towards the other end of the
heat shrink tube positioned over the cable.
Make sure that the glue is running out from
the end of the end sealing.
The heating cable is sealed/terminated
5
Standard compliance
•
IEC 60800 Heating cables with a rated voltage of 300/500 V for comfort heating and prevention
of ice formation.
•
KTW-BWGL - Testing and inspections on products and materials in contact with drinking water
(end termination).
Holder
Danfoss A/S
Product name, and relevant article number
Refer to the product label
Production site
Refer to the product label
Traceability to the production
To be found on insulation inside the cable
Cable length, nominal voltage, IP class, etc.
Refer to the product label
The registered trademark of Boverket No 241 217
Certification Body
Kiwa Certification AB
Accreditation number
1913
Type Approval No
TG 1747
Inspection Body
Danish Technological Institute (DTI)
Installation Guide Connection kit - cable to cold lead + end termination (Pipeheat)
13
DEVI