DEVIreg™ 233
Installation Guide
6
Follow the steps below to mount the thermostat:
1. Open the thermostat.
• Detach the front cover by inserting a small screw-
driver in the hole on top of the thermostat and
lifting the cover outwards.
• Loosen the two screws and carefully detach the unit.
2. Connect the thermostat according to the connection
diagram.
Max.
Load
13 (1) A
Mains
220-240V~
Sensor
D233
N L
L
N
Load
IP41
0T40
Danfoss A/S
Ulvehavevej 61
7100 Vejle
Denmark
Note: Always install the floor sensor in a conduit in the