AN324050550815en-000201 | 15
Danfoss © | 2020.07
Installation Guide
Danfoss ECdry Touch Kit
1�1
Connecting the ECdry elements
Bulges on the element may occur, but will
disappear when the ECdry system is heated.
All elements are equipped with an end stop
to insulate the connector and protect the
connection against moisture. Remove the
end stops with the special tool, just before
making the connection with the next heat-
ing mats. If all end stops are taken out at
once, remember to leave the end stop in the
last element.
Connect the plug-in connection of the second
element into the plug-in connection of the first
element. Put the male and female connector
together by hand before using the connec-
tor tool to push the elements tight together.
Check that the plug-in connection fits correctly
and permanently. Continue with the subse-
quent elements in the same manner.
Make sure that all plug-in connections fit
straight and without any mechanical stress.
Discontinue the floor heating installation
process in the event of damage to one or
more components. Incorrect installation may
cause problems and/or defects to the floor
heating mats. Please take precautions not to
drop sharp objects on the heating mats.
Use the enclosed aluminum tape to fix mats
to each other in order to secure connec-
tions and to avoid movement of mats. Place
aluminum tape in two positions: directly on
connections (between mat connections and
in the opposite end of the mat). In addition
fix 1
st
mat connection and output cord from
ECdry Touch Kit.
Make sure that the end stop in the last element
is in place before the floor covering is laid. Keep
the end stops if you intend to remove/reposi-
tion your floor heating system later.
1
2
2
1
20 cm
10 cm
20 cm
20 cm
20 cm
1
2
2
1