18 | Danfoss © | 2020.07
AN324050550815en-000201
Installation Guide
Danfoss ECdry Touch Kit
1�1
Mounting the ECtemp Thermostat
The electrical installation must be done by
an authorised electrician. Mount the ECtemp
thermostat to the wall. The ECtemp should be
installed in accordance with the instruction
manual supplied with the thermostat and the
ECdry Touch Kit.
Cut a piece of material from the filler mate-
rial to make room for the ECdry Supply Cord
between the ECtemp thermostat and the
ECdry Touch element.
Make sure not to fold and/or squeeze the
cord between the thermostat and the floor
heating element but make room for the cord
in the filler material. Minimum bending
diameter is 5 cm.
To place the sensor in the right spot, remove
the cut-away area in the ECdry Touch
heating element and place the sensor
down into the groove.
Fix the sensor to the heating mat with the
enclosed aluminium tape.
1�1
Checking the ECdry floor heating system
Check that all work has been carried out in
accordance with directions before testing
the ECdry floor heating system. Testing
may commence when everything has been
correctly connected. Read the directions for
the control system before you proceed. Set
the temperature at maximum 35 °C. After a
short while you will notice the ECdry floor
heating mats are warming up.
If the floor heating mats are not warming
up to the same temperature, the plug-in
connections should be checked once again.
Remember to switch off the ECdry system
before checking.