Installation Guide
Follow the steps below to mount the thermostat:
1. Click the thermostat on to the DIN rail attachment.
2. Connect the thermostat according to the connection
diagram.
IP20
-10T50
D316
12
11
10
9
8
7
L
6
5
4
3
2
1
N
Mains
220-240V
~
250V~
16 (1)
A
Sensor
Min.
Danfoss A/S
Ulvehavevej 61
7100 Vejle
Denmark
The screen of the heating cable must be connected
to the earth conductor of the power supply cable by
using a separate connector.
Note: When you use the wire sensor for floor heating,
always install the sensor in a conduit.
3. Turn on the power supply.
Protective separation
The thermostat is designed so that the sensor circuit is gal-
vanically separated from the high voltage part which means
that the sensor part is regarded as a low voltage part.