9.
Reassemble guiding plates and protective plates in the reverse
order.
10. For this purpose, use grease to fix one adjusting washer, each,
on the basedies before the guiding plates (4) are screwed on.
11. Perform a forming test run and check the formed sleeve.
Shims, if any, have to be placed at the same location as before.
After replacement of the slide bearing plates, the machine has to
be recalibrated (see CONTROL C.2 / IPC Operation Manual).
6.5 Replacement of relay/opto-coupler
1.
Deactivate the machine on the power switch and secure it
against unintentional restart.
2.
Open the control cabinet.
3.
Open the flap 90° and press down on the hinge with the opened
flap (1).
The relay/opto-coupler (2) will spring up.
4.
Remove the relay/opto-coupler and replace it by a new one.