FCM 300 Series
11
MG.03.B6.02 - VLT is a registered Danfoss trademark
Selection of FC motor
■
Ordering info for Frames and Flanges
Flange size according to IEC ref. FFxxx (Dimension M in chapter 6)
S: Available as standard shaft
A: Available as an alternative with specially elongated shaft to provide standard shaft for frame
B : Available as an alternative with standard shaft for frame, requiring no modification
Frame sizes and the corresponding flange sizes for different mounting versions
Type
Motor frame size
Mounting version
Flange size,
Flange size,
Flange size
standard (S)
alternatives (A)
alternatives (B)
4 pole
2 pole
[mm]
[mm]
[mm]
FCM 305
080MG 080MF
B5/B35
165
85/100/115/130
B14/B34
100
75/85/115/130/165
B5/B35
165
85/100/115/130
FCM 307
080MR 080MF
B14/B34
100
75/85/115/130/165
FCM 311
090LK
090SJ
B5/B35
165
100/115/130
215
B14/B34
115
85/100/130/165
B5/B35
165
100/115/130
FCM 315
090LT
090SJ
B14/B34
115
85/100/130/165
FCM 322
100LR
100LJ
B5/B35
215
165
B14/B34
130
165
85/100/115/215
B5/B35
215
165
FCM 330
100LT
100LM
B14/B34
130
165
85/100/115/215
FCM 340
112MT
112MS
B5/B35
215
115/130/165
B14/B34
130
165
85/100/115/215
FCM 355
132SJ
132SF
B5/B35
265
215
B14/B34
165
215
B5/B35
265
215
FCM 375
132MT
132SJ
B14/B34
165
215
■
Ordering info for inverter box position and drain hole position.