4.3 Thermostat registration 

To get the FH-BU base into registration mode

Press and hold “MODE” and “OK” buttons on base unit for 3 seconds, (all LED’s 
will flash) then release “MODE” and finally release “OK”. The system is now in 
registration mode. Only the “POWER” LED should be on (unless thermostats 
already have been assigned earlier- then the LED for these will be on)

Fig. 5. Registration mode 

Thermostat registration process

Using the point of a pencil press and release the thermostat transmission 
button. The  LED  for  the  first  available  channel  (1-8)  will  start  to  flash. 
Select the channel to be assigned to the thermostat by pressing the “MODE” 
button numerous times until the LED for the desired channel flashes. Then 
press and hold “OK” for 3 seconds (the LED will flash and finally be on). The 
thermostat is now registered. Repeat the thermostat registration process 
for each thermostat. (Also if one thermostat should be assigned to several 
channels).
After registering all thermostats, press and hold “MODE” for 3 seconds (all 
LED’s will flash), to return the system to normal mode. 

Note: 

The system returns automatically to normal mode if no buttons are 

pressed during a 5-minute period. 

4.4 De-registering thermostats 

To get the FH-BU base unit into de-registration mode

Press and hold “MODE” and “OK” buttons for 3 seconds, (all LED’s will flash) 
then  release “OK”,  and  finally  release “MODE”. The  system  is  now  in  de-
registration mode. (If only one thermostat is assigned the first assigned LED 
will start to flash).
Press the thermostat transmission button. The LED for the first assigned 
channel will start to flash, (the rest will be on). Select the channel to be de-
registered by pressing the “MODE” button numerous times until the LED for 
the desired channel flashes. Then press and hold “OK” for 3 seconds, (the LED 
will flash and finally go out). The channel is now de-registered. Repeat the 
thermostat de-registration process for each channel to be de-registered. 

After de-registering thermostats, press and hold the “MODE” button for 3 
seconds (all LED’s flash) to return the system to normal mode.

Fig. 6. De-registering thermostats 

Note: 

The system returns automatically to normal mode if no buttons are 

pressed during a 5-minute period.

4.5 Setting room temperature 

The temperature is set by turning the thermostat setting knob to the desired 
temperature. 

4.6 Setting min./max. temperature 

Lift thermostat cover. 
Set min./max. temperatures using the red and blue limiters respectively. 

4.7 Setting thermostat operating mode 

Switch position “sun” => normal => no night set-back. 
Switch position “moon” => night set-back => 4°C at 20°C. 
Switch position “clock” => timer-controlled set-back. 

If timer-controlled set-back is required, it must be programmed via the time 
clock/timer module (optional) fitted to the base unit. 

5.0  Special functions

5.1  Master reset 

This function deletes all registered data and reinstalls factory settings. 
Switch off the power supply, press and hold “OK” and “MODE” simultaneously 
and keep pressing them while switching the power back on. 
LED indicators 1-8 then light up consecutively, and finally all eight indicators 
flash. Release “OK” and “MODE”. 
The system has now been reset to initial factory settings. 

5.2 Transmission testing 

Transmission testing is used to test and identify all registered thermostats. 
Press and hold “OK” for 3 seconds (all LED indicators flash). 
All channels with assigned thermostats light up on the indicator panel. When 
a channel receives a signal from a thermostat, the corresponding indicator 
flashes twice and the indicators go off. If a signal is subsequently received 
from  the  same  thermostat,  the  indicator  for  the  corresponding  channel 
flashes twice. 
The test is automatically terminated once all channels have received a signal 
from their assigned thermostat. 