Place the switch in the
GRAVITY
position if the system being
controlled is a) fully pumped, but with only a single two port
zone valve in the Heating circuit, b)
GRAVITY
Hot Water,
PUMPED
Heating with no zone valves.
7 Day or 5/2 Day
When both switches are in the
7 DAY
position each day of the
week may be programmed with different
ON/OFF
times. When
both switches are in the
5 DAY/2 DAY
position, weekdays (Mon-Fri)
can be programmed with one set of
ON/OFF
times, and weekends
(Sat-Sun) can be programmed with a different set.
New Installation
1. Fix the wallplate to the wall or plaster box as required.
When
fi xing the wallplate note that the terminals are at
the top, and the vertical centre line of the unit lies between
terminals N & L.
2. Surface cables can only enter from below the unit. If
mounted on a plaster box, cables can enter from the rear
through the aperture in the wallplate.
3. The FP975 offers direct plug-in replacement to the
following models (see overleaf ):
Ne
w Installa
tion