Danfoss FT1244 Crimp Machine Operator’s Manual
AQ439269330776en-000101
© Danfoss FT1244 Crimp Machine Operator’s Manual | 2023.05. | 9
CRIMPING FIELD CRIMP STYLE HOSE ASSEMBLIES
Crimping field crimp style fittings requires special locating procedure. The fittings are located using the scribe lines on the socket of the
fitting (See illustration 4).
Maintenance
Normal maintenance of the FT1244 crimp machine requires a light film of oil coating over all the exposed black surfaces, crimp ring die,
contact surface lubricated with high efficiency PTFE grease (Danfoss part number T-400-G), and a maintained oil level within the hydraulic
power unit oil reservoir (one inch below the top of the reservoir).
Illustration 4