Danfoss FT1330 Crimp Machine Operator’s Manual
AQ439269212774en-000101
© Danfoss FT1330 Crimp Machine Operator’s Manual | 2023.02. | 7
Installation
The FT1330 crimp machine is delivered completely plumbed and wired. The reservoir has been filled with 10 weight hydraulic oil.
Install the machine on a solid bench capable of holding 245 pounds. Recommended bench height is 36”.
1. Uncrate the machine and position it in its work location on a bench capable of supporting a machine weighing 245 pounds. Allow
sufficient room behind the machine to provide access to the pump and reservoir for periodic maintenance or oil level inspection.
2. Anchor the machine securely to the bench using four 5/16 inch bolts. Holes are provided in the machine base for this purpose.
3. Position the toggle switch on the front of the cabinet in the “OFF” position.
4. Plug the power cord into a standard 115 or 230 volt single phase receptacle depending upon machine model. (The 115 volt electrical
circuit must be a 15 AMP dedicated circuit with 12 gauge wiring to the outlet. Do not use extension cords of any kind).
Tooling
CRIMP DIE CAGES
Crimp dies for the FT1330 crimp machine are contained in a die cage which can be inserted as a package into the machine, thus
eliminating time consuming and inaccurate insertion of individual dies. Each set of eight crimp dies for each size or style of crimp is
contained in a separate die cage, thus eliminating concern from inter-mixing dies of different sets.
Refer to the PowerSource Crimp Spec Tool at danfoss.com/crimp for crimp spec details including the proper crimp die cage part number
to use.